![Datasat AP25 Installation And Operating Manual Download Page 162](http://html2.mh-extra.com/html/datasat/ap25/ap25_installation-and-operating-manual_3699599162.webp)
AP25 Installation and Operating Guide
Version 1.00
Appendix H. Serial Command AP!
H-6
Document #: 9301H79500 Ver. 1.00
5.
Authorization
Command: @
AUTH
<space>
[Password]
<cr>
Operation
Response:
AUTH
<space>
[SETUP|OP|SECERR]
<cr>
Read
Give a password to allow usage of restricted commands. The authorization is required for many
commands if access the AP25 is configured with a Password. The
AUTH
must be issued before
issuing any password protected commands, and is valid only for the duration of the TCP/IP
connection.
There are two levels of password protection in the AP25. Both levels are set in the
System > Access
Control
screen on the AP25. The top password labeled
NetCmd Password
will allow access to the
AP25 for Operator level type commands. The bottom password labeled
Setup Password
allows
access to setup and configuration level commands.
The
AUTH
may be used for either the Operator or Setup level password.
Parameters:
[Password]
Operator level or
Setup level password. The AP25 compares this first with
setup level password and gives Setup Level authorization if it matches.
Otherwise, it compares it to the Operator (NetCmd) password and authorizes
operator commands if it matches.
SETUP
The AP25
returns this value when Setup Level authorization has been
granted.
OP
The AP25
returns this value when Operator Level authorization has been
granted.
SECERR
The AP25
returns this value if neither Setup nor Operator level authorization
has been granted.
6.
Serial Number
Command: @
SERIALNO
<CR>
Operation
Response:
SERIALNO
<space>
[SN]
<CR>
Read
Reads the AP25 serial number.
Parameters
[SN]
This value is the serial number that has been programmed into the unit during
the manufacturing process.