DATAMAN-48PRO2 / DATAMAN-48PRO2C
39
Selftest of programmer
Insert
48 pins diagnostic pod - type I
into ZIF socket of the programmer.
48 pins
diagnostic pod - type I
must be inserted as 48 pins device.
Run selftest of programmer in PG4UW (menu Programmer / Selftest).
Selftest of ISP connector
Insert
Diagnostic pod for ISP connectors #2
into ZIF socket of the programmer.
Diagnostic pod for ISP connectors #2
must be inserted as 48 pins device.
Interconnect 20 pins connector of
Diagnostic pod for ISP connectors #2
with an ISP
connector of the programmer with an ISP cable, included in delivery programmer package.
Be sure that pins are interconnected properly (i.e. 1-1, 2-2 ... 20-20).
Run selftest of ISP connector in PG4UW (menu Programmer / Selftest ISP connector…).