126
1. by using menu command
Options / Protected mode
. This command displays password
dialog. User has to enter password twice to confirm the password is correct. After
password confirmation program switches to Protected mode. The entered password is
then used to switch off Protected mode.
2. by reading project, that was previously saved in Protected mode. For details see
File /
Save project
.
Checkbox
Keep "Load project" operation allowed
is set to inactive state by default - it
means the Load project operation button and menu will be disabled when Protected mode is
active.
If the option is enabled (checked), the Load project operation button and menu will be allowed
in Protected mode.
Checkbox
Disable view/edit buffer
is set to inactive state by default - it means the View/Edit
buffer button and menu will be enabled when Protected mode is active. This allows you and
others to view content of buffer, but not edit (due to active Protected mode).
Activate this option, if you wish to disable also viewing of buffer content in Protected mode. In
this case, we recommend activating also option Encrypt project file (with password). For details
see File / Save project.
Select operation mode for protected mode
Options
"Multi operation" mode
- represents basic form of protected mode, where all
available device operations (blank, verify, program, erase) are enabled, except read. This
provides certainty, that operator cannot modify buffer data by accidental or intentional read
operation. It's useful when you want to have all supported device operations enabled in one
project (multi-project).
Options
"One operation" mode
- represents
enhanced form of protected mode
, where
only one operation
from all available
is enabled
. Provides better certainty, because prevents
operator from executing wrong type of device operation.
By
building
more projects saved in "One operation" mode using Multi-project Wizard you can
put together also non-standard
flow
of
device operations
of control SW (e.g. Program +
Verify). Please, see examples of use and differences between operation
modes.
To switch program from Protected mode to
Normal mode
, use the menu command
Options /
Normal mode
. The ”
Password required
" dialog appears. User has to enter the same
password as the password entered during switch to Protected mode.
Other way to
cancel Protected mode
of program is closing of program. Next time the program
starts in Normal (standard) mode (the only exception is case of project loaded by command
line parameter with name of project which was saved in Protected mode).
When Protected mode is active, the software indicates this by
label Protected mode
in right
top corner of Programmer activity log.
If you search information about another option
Require project file unique ID before first
programming
, indicated by
label (ID)
next to project file name in bottom status line of control
program, please take a look at chapter File / Save project.
Summary of Contents for 40PRO
Page 7: ...Introduction 7 Introduction ...
Page 12: ...12 Quick Start ...
Page 15: ...Detailed description 15 Detailed description ...
Page 16: ...16 DATAMAN 448PRO2 ...
Page 30: ...30 DATAMAN 48PRO2 DATAMAN 48PRO2C ...
Page 46: ...46 DATAMAN 40PRO ...
Page 55: ...Setup 55 Setup ...
Page 60: ...60 Step 8 Installation process will start Step 9 Click Finish button to finish setup ...
Page 66: ...66 PG4UW ...
Page 133: ...PG4UWMC 133 PG4UWMC ...
Page 146: ...146 Installation procedure customized ...
Page 151: ...Common notes 151 Common notes ...
Page 165: ...Troubleshooting and warranty 165 Troubleshooting and warranty ...