124
the result of previous operation and the LED Busy is blinking. If the program detects removal of
a device from ZIF socket, then the status LED goes off, but the LED Busy is still blinking to
indicate readiness of the program to repeat last operation with new device. After the program
indicates one or more pins of (new) device in the ZIF socket, the LED Busy goes light
continually. From this point the program waits a requested time for insertion of the rest pins of
new device. If a requested time (Device insertion complete time) overflows and a device is not
correctly inserted, the program will light the LED Error to indicate this state. When new device
is inserted correctly, the status LED goes off and a new operation with device is started.
Remote control
Remote control of PG4UW control program allows controlling some functions of PG4UW
application by other application. This is very suitable feature for integrating device programmer
to mass-production handler system or other useful application.
Remote application that controls PG4UW acts as Server. Program PG4UW acts as Client.
Communication between PG4UW and remote control program is made via TCP protocol - this
allows the PG4UW to be installed on one computer and remote control application to be
installed on another computer and these computers will be connected together via network.
Default TCP communication settings for remote control are:
Port:
telnet
Address:
127.0.0.1
or
localhost
Address setting applies for PG4UW (Client) only. Port setting applies for PG4UW (Client) and
also for Server application.
Default settings allow using remote control on one computer (address localhost). PG4UW
(Client) and remote control Server have to be installed on the same computer.
Note:
If firewall is installed on system, firewall can display warning message when remote
control Server or Client is starting. When firewall is showing warning with question asking to
allow or deny network access for remote Server or Client, please select 'Allow' option,
otherwise remote control will not work. Of course you can specify in firewall options more strict
rights to allow remote Server/Client access on specified address and port only.
For more information about remote control of PG4UW and demonstration remote control
applications, please see the application note
remotemanual.pdf
placed in subdirectory
\RemoteCtrl which is in the directory, where PG4UW is installed. Manual for remote control is
available also from Windows Start / Programs menu link to Remote manual, created during
PG4UW installation.
Save options
Page allows you to select the program options saving when exiting program. Three options are
available here:
Don't save
don't save options during quitting program and don't ask for saving options
Auto save
save options during quitting program without asking for saving options
Prompt for save
program asks user for saving options before quitting program. User can
select to save or not to save options
Other
Page
Other
allows user to manage other program settings.
Summary of Contents for 40PRO
Page 7: ...Introduction 7 Introduction ...
Page 12: ...12 Quick Start ...
Page 15: ...Detailed description 15 Detailed description ...
Page 16: ...16 DATAMAN 448PRO2 ...
Page 30: ...30 DATAMAN 48PRO2 DATAMAN 48PRO2C ...
Page 46: ...46 DATAMAN 40PRO ...
Page 55: ...Setup 55 Setup ...
Page 60: ...60 Step 8 Installation process will start Step 9 Click Finish button to finish setup ...
Page 66: ...66 PG4UW ...
Page 133: ...PG4UWMC 133 PG4UWMC ...
Page 146: ...146 Installation procedure customized ...
Page 151: ...Common notes 151 Common notes ...
Page 165: ...Troubleshooting and warranty 165 Troubleshooting and warranty ...