SC4000 REFERENCE MANUAL
40
6
Layout
SC4000
Parameters
ID-NET™ Synchronized
Master/Fieldbus Slave
to Host Fieldbus Master
(ex: DEVICENET)
Note
Net Type Rotary Switch
3
Fieldbus Interface
Board =
BM4x0
Address Rotary Switches
X100 = 0
X10 = 0..6
X1 = 0..9
Address Range=
00..63
Topology Role
Master (
SYNCHRONIZED
)
System Layout / Host 1 Serial Port Type
Devicenet
Communication Settings / Gateway / Status
<checked>
Communication Settings / Gateway / Data Tx
<checked>
Communication Settings / Gateway / Bus
Communication / Node Address
Aligned to the Fieldbus
Master configuration
Communication Settings / Gateway / Bus
Communication / (Master Input Area Size,
Master Output Area Size, Data Flow Control,
Data Consistency)
According to the Fieldbus
application
Communication Settings / Host 2 Serial Port /
Line Parameters / Communication Protocol
Standard
Data Source device
to Host 2
Communication Settings / Host 2 Serial Port
/ Line Parameters/ (Electrical Interface, Baud
Rate, Parity, Data Bits, Stop Bits)
Aligned to the Data Source
device configuration
Data Source device
to Host 2
Communication Settings / Host 2 Serial Port /
Data Pass Through
<checked>
Data Source device
to Host 2
Communication Settings / Host 2 Serial Port /
Data Pass Through Options / Data
Destination: Gateway
<checked>
Data Source device
to Host 2
Communication Settings / Host 2 Serial Port /
Data Pass Through Options / Termination
String
Aligned to the Data Source
device configuration
Data Source device
to Host 2