SC4000 REFERENCE MANUAL
4
All Reading Devices (except 6K/8K)
to Earth (default)
to GND
Floating
6K, 8K Family Scanners
The scanner chassis is
internally connected to GND
to Earth (default)
Figure 5 – Chassis Grounding
4.1.4 ID-NET/Host 1 Shield Jumper Settings
The Network shield (Shield) can be connected to Earth Ground (Earth) either directly or
through a filter circuit. If the jumper is left open, the network cable shield (Shield) is floating.
Filtered Earth
(default)
Earth
floating
Equivalent
Filter Circuit
Figure 6 - ID-NET/Host 1 Shield Jumper Settings
4.2 NETWORK BUS TERMINATION
4.2.1 ID-NET™ Termination
OFF ON
Figure 7 – ID-NET™ Termination Resistance Switch
The ID-NET™ termination resistance switch enables or disables the insertion of the bus
termination resistor for ID-NET™ network applications.
CAUTION
In ID-NET™ network applications the termination resistor must be enabled
ONLY on the first and last devices of the chain. On all the other devices this
resistor MUST NOT be enabled (OFF).
10