SC4000 REFERENCE MANUAL
6
2
2.3 MECHANICAL INSTALLATION
SC4000 can be mounted to various wooden or plastic surfaces using two self-threading screws
(3.9 x 45 mm) and washers.
Mounting to other surfaces such as concrete walls or metallic panels requires appropriate
user-supplied parts (screws, screw anchors, nuts, etc).
SC4000 can also be mounted to a DIN rail or a Bosch Frame using the following mounting
accessories: BA100 (93ACC1821), BA200 (93ACC1822).
2.4 OPENING THE SC4000
To install the SC4000 or during normal maintenance, it is necessary to open it by unscrewing
the four cover screws:
CAUTION
The SC4000 must be disconnected from the power supply during this
operation.
2.5 ACCESS TO INTERNAL PARTS
To make installation and replacement easier, the SC4000 is made up of three parts:
1) the body of the device containing all electronic components and optional boards
2) the transparent removable cover for inspection and for easy access to spring clamps
and internal modules
3) the removable front connector panel providing easy access to the serial and optional
interface modules
Figure 2 – SC4000 Front Connector Panel