SC4000 REFERENCE MANUAL
8
Reading Result (Master Synchronized only)
G o o d
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4
5 6 7 8 9
0 2 C o
d
e s
When not in Single Label, the reading result (Good, Part, Mult, etc.) is followed by the code
data (without separation) and the number of codes read in the reading phase.
G o o d
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4
5 6 7
1 8 D G T F
When in Single Label, the reading result is followed by the code data (single code), the
number of digits in the code and the direction in which the code was read, where:
F
= Forward
direction
R
= Reverse
direction
U
= Unknown
direction
Reading Mask (Master Synchronized only)
P a r t i a l
R e a d
G 0 9 9 % N 0 0 0 % M 0 0 0 % P 0 0 1 %
0 0 1 1 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Four percentage counters display the reading results of the last 100 codes. The bit mask
shows which slaves read codes: 0 = not read, 1 = read.
Welcome Message
S C 4 0 0 0
S T D
1 . 0 . 0
M U L
M 0 0
L 1
F . B U S : E t h e r n e t T C P /
I P
Display lines one and two show the SC4000 model and software version. Line three shows
the Topology Role:
MUL
=
SC4000 Multidata Topology Role
SYN
=
SC4000 Synchronized Topology Role
ALN
=
SC4000 Other Topology Role
M00
=
SC4000 ID-NET network Master (always 00)
Sxx
=
SC4000 ID-NET network Slave address
Line four shows the Host Interface Type.