100 Setup
AccuVision
®
AV6010 Long-Range Camera System Manual
Accu-Sort Systems, Inc.
05-AV6010_Setup_R10.doc
Top Camera Wizard
This wizard is used to learn the Top camera’s position.
Setup for Top, Top-Front or Top-Back cameras is similar.
The icon will appear different based on the camera orientation.
Prerequisites:
Know the top camera angle required by the system.
It will be one of the following:
15-degrees (positive angle)
15-degrees (negative angle)
8-degrees (positive angle, used in dimensioning systems)
RangeFinder must already be calibrated
Mirror must already be aligned
Tools Required:
Small calibration box
Camera Scan Line Target
Static Focus Target
Tape measure
Laptop with Install Wizard connected to camera system
NOTE:
The Small Calibration Box and targets are provided in the
AV6010 Setup & Calibration Kit
(part number 111456001). The targets
are also available from the AV6010 user interface. Go to:
Diagnostics >
Tools
and click the
Utilities and Documentation
link.
To auto-calibrate the Top Camera:
Follow the camera wizard’s instructions to perform the static auto-calibration.
1. Click the
Top Read
Wizard button.
2. Set the
Top Camera Angle Orientation Selector
for either Top-Front or
Top-Back. Camera angle facing upstream is negative (Top-Front).
Camera angle facing downstream is positive (Top-Back).
3. Use the Camera Scan Line Target to determine the distance from the
camera to the focus source (RangeFinder). Enter this measurement as
the
X Scan Offset
.
4. Use the small calibration box and Camera Scan Line Target to determine
the
X Distance.
5. The system uses the previously entered information to compute the
camera’s read angle. Do not change unless otherwise instructed.
6. Use the Static Focus Target to determine the camera’s far working
distance.
7. Review the
Calibration Results Summary
for the camera.
NOTE:
The wizards for other camera orientations function in a similar
manner. Follow the camera wizard’s step-by-step instructions to complete
the auto-calibration for a multi-camera system.