![Dantel 46062-02 Installation & Operation Manual Download Page 9](http://html1.mh-extra.com/html/dantel/46062-02/46062-02_installation-and-operation-manual_3459426009.webp)
46062-0299 <90-00016>
P
AGE
9
F
IG
. 6 - P
RINTER
P
ORT
D
ATA
R
ATE
S
WITCH
S
ETTINGS
SWITCH 3
S1-1
S1-2
DIP Switch 1-
S1-3
Baud
S1-1
S1-2
S1-3
50
ON
ON
ON
110
OFF
ON
ON
300
ON
OFF
ON
600
OFF
OFF
ON
1200
ON
ON
OFF
2400
OFF
ON
OFF
4800
ON
OFF
OFF
9600
OFF
OFF
OFF
General Purpose
Processor (GPP)
SWITCH 1
SWITCH 2
SWITCH 1
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
F
IG
. 7 - M
ASTER
P
ORT
D
ATA
R
ATE
S
WITCH
S
ETTINGS
SWITCH 3
SWITCH 2
SWITCH 1
S1-4
S1-5
DIP Switch 1-
S1-6
Baud
S1-4
S1-5
S1-6
50
ON
ON
ON
110
OFF
ON
ON
300
ON
OFF
ON
600
OFF
OFF
ON
1200
ON
ON
OFF
2400
OFF
ON
OFF
4800
ON
OFF
OFF
9600
OFF
OFF
OFF
General Purpose
Processor (GPP)
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
SWITCH 1
1 2 3 4 5 6 7 8
INSTALLATION