-40
-
■
■
■
■
ALARM
<Main Menu>
<ALARM>
This model of speed dome has 7 alarm input
channels and 2 output. Alarm input signal can come
from other devices such as infrared detector and
alarm output signal can go to light and DVR etc.
<Alarm in 1 ~ Alarm in 7>
Channel 1 has the highest priority and channel 7 has
the lowest priority. Set the alarm input and the
dome’s corresponding action. Following options are
applicable.
[Off] Disable the alarm input (default)
[Pre 001~256] Call preset 001~256
[Cru 001~008] Run auto scan 001~008
[Tour 001~008] Run tour 001~008
[Pat 001~008] Run pattern 001~008
NOTE: There are two alarm output methods: NO
and NC, refer to Appendix I for setting details.
For example:
In this example, when the first alarm is activated,
the dome will run preset-001; when the second
alarm is activated, the doom will run pattern-3;
when the third alarm is activated, the doom will run
autoscan-2; When the fourth alarm is activated, the
PTZ dome will run tour-1.
Relay 1~2: Relays the alarm input signal to other
devices. e.g. light and DVR. Change the option to
switch the alarm output ON or OFF. Default setting
is OFF
<Arm/Disarm>
Arm or disarm the alarm system and show the
status.
<Interval >
Set the time after which the
alarm will be reset. Values are in second unit,
default setting is 4.
[001~255] Reset within the number of seconds.
<Back>
Back to main menu.
Alarm in 1: Off
Alarm in 2: Off
Alarm in 3: Off
Alarm in 4: Off
Alarm in 5: Off
Alarm in 6: Off
Alarm in 7: Off
Relay 1: Off
Relay 2: Off
Arm/Disarm: Armed
Interval: 030
Back
Alarm in 1 : Pre. 001
Alarm in 2 : Pat. 003
Alarm in 3 : Cru. 002
Alarm in 4 : Tour 001
Alarm in 5 : Off
Alarm in 6 : Off
Alarm in 7 : Off
Relay 1 : Off
Relay 2 : Off
Arm/Disarm: Arm
Interval <S>: 004
Back