-38
-
■
■
■
■
PARK TIME
<Main Menu>
<Auto Running>
<Park Time>
This function let the system automatically run an
assigned function after a specific period of idle time.
For example: the dome is running a tour and an
operator breaks the tour to do other work, the dome
can automatically carry on the tour within a period
of time after the operator stops his operation.
<Park Time>
Park time means a period of idle time without any
operation.
The values includes: OFF, 001~255.
[Off]: Disable this function.
[001~255]: Auto run a function after the number
seconds of idle time.
<Park Action>
Park action refers to the function that system will
automatically run when park time is up.
The function could be:
[Off] Disable this function
[Pre 001~220] Call preset 001~220
[Cru 001~004] Run auto scan 001~004
[Tour 001~006] Run tour 001~006
[Pat 001~006] Run pattern 001~006
In this example, system will run Preset-8 after 38
seconds of idle time.
Preset
Tour
Pattern
Cruise
Zone
Park Time: Off
Park Action: Off
Back
Preset
Tour
Pattern
Cruise
Zone
Park Time: 038
Park Action: Pre008
Back