Pa
r.
No.
#
Para
mete
r descripti
on
De
fault va
lue
4-
se
t-
up
FC
3
02
onl
y
Cha
nge
durin
g
ope
rati
on
Conve
r-
sio
n index
Type
1-
0* Gen
er
al Set
ti
n
g
s
1-0
0
Configura
tio
n Mode
null
All
set
-ups
TRUE
-
Uint8
1-0
1
M
otor Con
trol
Pr
in
cipl
e
null
All
set
-ups
FALSE
-
Ui
nt8
1-0
2
Fl
ux Mot
or Feed
back S
ource
[1
]
24
V encod
er
All
set
-ups
x
FALSE
-
U
int8
1-0
3
Torque
Cha
racte
ristics
[0
] C
onsta
nt torque
All
set
-ups
TRUE
-
Ui
nt8
1-0
4
O
verl
oad
Mo
de
[0] Hi
gh torq
ue
All
se
t-
ups
FALSE
-
U
int8
1-0
5
Local Mode
Conf
ig
ura
tion
[2
] As mo
de
par
1-
00
All
set
-ups
TRUE
-
Ui
nt8
1-
1* Mot
o
r
S
ele
ct
ion
1-1
0
M
otor Constru
ct
ion
[0
] A
syn
ch
ro
n
All
set
-ups
FALSE
-
Ui
nt8
1-
2* Mot
o
r
Dat
a
1-2
0
M
otor Power [
kW]
Ex
pression
Limit
All
set
-ups
FALSE
1
Ui
nt32
1-
21
M
otor Power [
H
P]
Expression
Li
mi
t
All
set
-ups
FALSE
-2
Ui
nt32
1-2
2
Mo
to
r V
olt
ag
e
Ex
pression
Limit
All
set
-ups
FALSE
0
Ui
nt16
1-
23
M
otor Frequ
ency
Expression
Li
mi
t
All
set
-ups
FALSE
0
U
in
t16
1-2
4
M
otor Curre
nt
Ex
pression
Limit
All
set
-ups
FALSE
-2
Ui
nt32
1-
25
M
otor Nomi
na
l Speed
Ex
pression
Li
mi
t
All
set
-ups
FALSE
67
Ui
nt16
1-2
6
M
otor
Cont.
Ra
ted Torque
Ex
pression
Limit
All
set
-ups
FALSE
-1
Ui
nt32
1-2
9
Automa
tic Mot
or Adapta
tion (AMA
)
[0] Off
All
set
-ups
FALSE
-
Ui
nt8
1-
3* Addl
. M
o
tor
D
ata
1-3
0
Stat
or Re
sista
nce (Rs)
Ex
pression
Limit
All
set
-ups
FALSE
-4
Ui
nt32
1-3
1
Roto
r Re
sist
ance
(R
r)
Ex
pression
Limit
All
set
-ups
FALSE
-4
Ui
nt32
1-
33
Stat
or Lea
kag
e Re
acta
nce (X
1)
Ex
pressi
on
Limit
Al
l set
-up
s
FALSE
-4
U
int3
2
1-3
4
Roto
r Le
aka
ge R
eacta
nce (
X2)
Ex
pression
Limit
All
set
-ups
FALSE
-4
Ui
nt32
1-
35
M
ai
n R
ea
ct
ance (Xh)
Ex
pression
Li
mi
t
All
set
-ups
FALSE
-4
Ui
nt32
1-3
6
Iron
Loss
Resi
sta
nce (
R
fe)
Ex
pression
Limit
All
set
-ups
FALSE
-3
Ui
nt32
1-
37
d-a
xi
s I
nduc
ta
nc
e (
Ld
)
Ex
pressi
on
Limit
Al
l set
-up
s
x
FA
LSE
-4
Int
32
1-3
9
Mo
to
r Po
le
s
Ex
pression
Limit
All
set
-ups
FALSE
0
Ui
nt8
1-4
0
Back EMF at 1
000 R
PM
Exp
re
ssio
nLi
mi
t
All
se
t-
ups
x
FALSE
0
Ui
nt16
1-4
1
Mo
tor Angl
e
O
ff
set
0 N/
A
All
set
-ups
FALSE
0
Int
16
1-
5* Load-I
nd
ep.
S
ett
in
g
1-5
0
Mo
to
r
Ma
gn
et
iz
at
io
n a
t Z
er
o
Sp
ee
d
10
0 %
All
set
-ups
TRUE
0
Ui
nt16
1-
51
Mi
n
Sp
ee
d
No
rma
l Mag
neti
zin
g [
R
PM]
Ex
pressi
on
Limit
Al
l set
-up
s
TRUE
67
U
int1
6
1-5
2
Mi
n S
pee
d N
orma
l Ma
gne
tiz
in
g
[H
z]
Ex
pression
Limit
All
set
-ups
TRUE
-1
Ui
nt16
1-
53
M
odel Sh
ift
Frequency
Expression
Li
mi
t
All
set
-ups
x
FALSE
-1
U
in
t16
1-5
5
U/f Cha
racte
ristic -
U
Ex
pression
Limit
All
set
-ups
TRUE
-1
Ui
nt16
1-
56
U/f Cha
racte
ristic -
F
Expressi
on
Li
mi
t
All
set
-ups
TRUE
-1
U
in
t16
4.3.2.
1-** Load/Motor
4. How to Program
VLT
®
Automation Drive FC 300
Instruction Manual High Power
86
MG.33.U1.22 - VLT
®
is a registered Danfoss trademark.
4