13-44 Logic Rule Boolean 3
Array [6]
Select the third boolean (TRUE or FALSE) input for the selected
logic rule.
See
parameter 13-40 Logic Rule Boolean 1
for further descriptions
of options and their functions.
Option:
Function:
[73]
SL Time-out 6
[74]
SL Time-out 7
3.9.6 13-5* States
13-51 SL Controller Event
Array [20]
Select the boolean input (TRUE or FALSE) to define the smart
logic controller event.
See
for further descriptions of options
and their functions.
Option:
Function:
[0]
*
False
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[7]
Out of current
range
[8]
Below I low
[9]
Above I high
[16]
Thermal
warning
[17]
Mains out of
range
[18]
Reversing
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip
lock)
[22]
Comparator 0
[23]
Comparator 1
[24]
Comparator 2
[25]
Comparator 3
[26]
Logic rule 0
[27]
Logic rule 1
[28]
Logic rule 2
[29]
Logic rule 3
[30]
SL Time-out 0
[31]
SL Time-out 1
[32]
SL Time-out 2
[33]
Digital input
DI18
[34]
Digital input
DI19
[35]
Digital input
DI27
13-51 SL Controller Event
Array [20]
Select the boolean input (TRUE or FALSE) to define the smart
logic controller event.
See
for further descriptions of options
and their functions.
Option:
Function:
[36]
Digital input
DI29
[39]
Start
command
[40]
Drive stopped
[42]
Auto Reset
Trip
[50]
Comparator 4
[51]
Comparator 5
[60]
Logic rule 4
[61]
Logic rule 5
[70]
SL Time-out 3
[71]
SL Time-out 4
[72]
SL Time-out 5
[73]
SL Time-out 6
[74]
SL Time-out 7
13-52 SL Controller Action
Array [20]
Select the action corresponding to the SLC event. Actions are
executed when the corresponding event (defined in
parameter 13-51 SL Controller Event
) is evaluated as true. The
following actions are available for selection:
Option:
Function:
[0]
*
Disabled
[1]
No action
[2]
Select set-up 1 Changes the active set-up
(
parameter 0-10 Active Set-up
) to 1.
[3]
Select set-up 2 Changes the active set-up
(
parameter 0-10 Active Set-up
) to 2.
[10]
Select preset
ref 0
Selects preset reference 0.
[11]
Select preset
ref 1
Selects preset reference 1.
[12]
Select preset
ref 2
Selects preset reference 2.
[13]
Select preset
ref 3
Selects preset reference 3.
[14]
Select preset
ref 4
Selects preset reference 4.
[15]
Select preset
ref 5
Selects preset reference 5.
[16]
Select preset
ref 6
Selects preset reference 6.
[17]
Select preset
ref 7
Selects preset reference 7. If the
active preset reference is changed,
it merges with other preset
Parameters
VLT
®
Compressor Drive CDS 803
52