5 Parameter Lists
5.1 Parameter Options
5.1.1 Default Settings
Changes during operation
True: The parameter can be changed while the frequency
converter is in operation.
False: The parameter can only be changed when the
frequency converter stops.
2-Set-up
All set-ups: The parameter can be set individually in each
of the 2 set-ups. 1 single parameter can have 2 different
data values.
1 set-up: Data value is the same in all set-ups.
ExpressionLimit
Size-related
N/A
No default value available.
Conversion index
This number refers to a conversion figure used when
writing or reading via a frequency converter.
Conv.
index
100
75
74
70
67
6
5
4
3
2
1
0
-1
-2
-3
-4
-5
-6
Conv.
factor
1
3600000
3600
60
1/60
1000000 100000 10000
1000
100
10
1
0.1
0.01
0.001 0.0001 0.00001 0.000001
Data type
Description
Type
2
Integer 8
Int8
3
Integer 16
Int16
4
Integer 32
Int32
5
Unsigned 8
Uint8
6
Unsigned 16
Uint16
7
Unsigned 32
Uint32
9
Visible string
VisStr
33
Normalized value 2 bytes
N2
35
Bit sequence of 16 boolean variables
V2
Table 5.1 Data Type
Parameter Lists
Programming Guide
MG18P202
Danfoss A/S © 06/2019 All rights reserved.
75
5
5