40% duty cycle, vertical braking, T7
FC 302
Vertical braking 40% duty cycle
Frequency converter data
Brake resistor data
Installation
R
rec
[
Ω
]
P
br,cont.
[kW]
Danfoss part number
Cable
cross-
section
[mm
2
]
Thermo
relay
[A]
Mains
type
P
m
[kW]
R
min
[
Ω
]
R
br,nom
[
Ω
]
Wire IP54
Screw
terminal
IP21
Screw
terminal
IP65
Bolt
connection
IP20
T7
1.1
620
830
630
0.360
-
175u3108 175u3109
-
1.5
0.8
T7
1.5
513
600
570
0.570
-
175u3110 175u3111
-
1.5
1
T7
2.2
340
403
415
0.790
-
175u3112 175u3113
-
1.5
1.3
T7
3
243
292
270
1.130
-
175u3118 175u3119
-
1.5
2
T7
4
180
216
200
1.700
-
175u3122 175u3123
-
1.5
2.8
T7
5.5
130
156
145
2.200
-
175u3106 175u3107
-
1.5
3.7
T7
7.5
94
113
105
3.200
-
175u3132 175u3133
-
1.5
5.2
T7
11
69.7
76.2
72
4.200
-
175u3142 175u3143
-
1.5
7.2
T7
15
46.8
55.5
52
6.000
-
-
-
175u3242
2.5
10.8
T7
18.5
36.0
44.7
42
8.000
-
-
-
175u3243
2.5
13.9
T7
22
29.0
37.5
31
10.000
-
-
-
175u3244
4
18
T7
30
22.5
29.1
27
14.000
-
-
-
175u3201
10
23
T7
37
18.0
23.5
22
17.000
-
-
-
175u3202
10
28
T7
45
13.5
19.3
15.5
21.000
-
-
-
175u3205
16
37
T7
55
13.5
15.7
13.5
26.000
-
-
-
175u3209
16
44
T7
75
8.8
11.5
11
36.000
-
-
-
175u3212
25
57
T7
90
8.8
9.5
9.1
42.000
-
-
-
175u3214
35
68
T7
110
6.6
7.8
7.4
52.000
-
-
-
175u3215
50
84
T7
132
4.2
6.4
6.1
60.000
-
-
-
175u3218
70
99
T7
160
4.2
5.3
5.0
78.000
-
-
-
175u3220
2x35
125
T7
200
3.4
4.2
4.0
90.000
-
-
-
175u3222
2x35
150
T7
250
2.3
3.4
3.2
-
-
-
-
-
-
-
T7
315
2.3
2.7
2.5
-
-
-
-
-
-
-
T7
355
2.0
2.4
2.3
-
-
-
-
-
-
-
T7
400
1.9
2.1
2.0
-
-
-
-
-
-
-
T7
500
1.5
1.7
1.6
-
-
-
-
-
-
-
T7
560
1.4
1.5
1.4
-
-
-
-
-
-
-
T7
630
1.2
1.3
2x2.6
-
-
-
-
-
-
-
T7
710
1.1
1.2
2x2.2
-
-
-
-
-
-
-
T7
800
1.0
1.1
2x2.0
-
-
-
-
-
-
-
T7
900
0.9
0.9
3x2.6
-
-
-
-
-
-
-
T7
1000
0.8
0.8
3x2.4
-
-
-
-
-
-
-
T7
1200
0.7
0.7
3x2.0
-
-
-
-
-
-
-
Table 8.30 T7, Vertical Braking 40% Duty Cycle
Selection Guide
Design Guide
56
Danfoss A/S © Rev. 05/2014 All rights reserved.
MG90O202
8
8
Summary of Contents for VLT Brake Resistor MCE 101