40% duty cycle, vertical braking, T4
FC 360
Vertical braking 40% duty cycle
Frequency converter data
Brake resistor data
Installation
R
rec
[
Ω
]
P
br,cont.
[kW]
Danfoss part number
Cable
cross-
section
[mm
2
]
Thermo
relay
[A]
Mains
type
P
m
[kW]
R
min
[
Ω
]
R
br,nom
[
Ω
]
Wire IP54
Screw
terminal
IP21
Screw
terminal
IP65
Bolt
connection
IP20
T4
0.37
890
1042
1200
0.200
175u3101
-
-
-
1.5
0.4
T4
0.55
593
694
850
0.200
175u3308
-
-
-
1.5
0.5
T4
0.75
434
509
630
0.300
175u3309
-
-
-
1.5
0.7
T4
1.1
288
338
410
0.450
175u3310 175u3416
175u3415
-
1.5
1
T4
1.5
208
244
270
0.570
175u3311 175u3418
175u3417
-
1.5
1.4
T4
2.2
139
164
200
0.960
175u3312 175u3420
175u3419
-
1.5
2.1
T4
3
100
119
145
1.130
175u3313 175u3422
175u3421
-
1.5
2.7
T4
4
74.0
87.9
110
1.700
175u3314 175u3424
175u3423
-
1.5
3.7
T4
5.5
54.0
63.3
80
2.200
175u3315 175u3138
175u3139
-
1.5
5
T4
7.5
38.0
46.1
56
3.200
175u3316 175u3428
175u3427
-
1.5
7.1
T4
11
27.0
33.0
38
5.000
-
-
-
175u3236
1.5
11.5
T4
15
19.0
24.0
28
6.000
-
-
-
175u3237
2.5
14.7
T4
18.5
16.0
19.4
22
8.000
-
-
-
175u3238
4
19
T4
22
16.0
18.0
19
10.000
-
-
-
175u3203
4
23
T4
30
11.0
13.8
14
14.000
-
-
-
175u3206
10
32
T4
37
9.0
11.1
12
17.000
-
-
-
175u3210
10
38
T4
45
8.0
9.1
9.5
21.000
-
-
-
175u3213
16
47
T4
55
6.0
7.4
7.0
26.000
-
-
-
175u3216
25
61
T4
75
4.0
5.4
5.5
36.000
-
-
-
175u3219
35
81
Table 8.32 T4, Vertical Braking 40% Duty Cycle
Selection Guide
Design Guide
58
Danfoss A/S © Rev. 05/2014 All rights reserved.
MG90O202