8.2.7 VLT
®
AutomationDrive FC 360
10% duty cycle, horizontal braking, T4
FC 360
Horizontal braking 10% duty cycle
Frequency converter data
Brake resistor data
Installation
R
rec
[
Ω
]
P
br,cont.
[kW]
Danfoss part number
Cable
cross-
section
[mm
2
]
Thermo
relay
[A]
Mains
type
P
m
[kW]
R
min
[
Ω
]
R
br,nom
[
Ω
]
Wire IP54
Screw
terminal
IP21
Screw
terminal
IP65
Bolt
connection
IP20
T4
0.37
890
1042
1200
0.100
175u3000
-
-
-
1.5
0.3
T4
0.55
593
694
850
0.100
175u3001
-
-
-
1.5
0.4
T4
0.75
434
509
630
0.100
175u3002
-
-
-
1.5
0.4
T4
1.1
288
338
410
0.100
175u3004
-
-
-
1.5
0.5
T4
1.5
208
244
270
0.200
175u3007
-
-
-
1.5
0.8
T4
2.2
139
164
200
0.200
175u3008
-
-
-
1.5
0.9
T4
3
100
119
145
0.300
175u3300
-
-
-
1.5
1.3
T4
4
74.0
87.9
110
0.450
175u3335
175u3450
175u3449
-
1.5
1.9
T4
5.5
54.0
63.3
80
0.570
175u3336
175u3452
175u3451
-
1.5
2.5
T4
7.5
38.0
46.1
56
0.680
175u3337
175u3027
175u3028
-
1.5
3.3
T4
11
27.0
33.0
38
1.130
175u3338
175u3034
175u3035
-
1.5
5.2
T4
15
19.0
24.0
28
1.400
175u3339
175u3039
175u3040
-
1.5
6.7
T4
18.5
16.0
19.4
22
1.700
175u3340
175u3047
175u3048
-
1.5
8.3
T4
22
16.0
18.0
19
2.200
175u3357
175u3049
175u3050
-
1.5
10.1
T4
30
11.0
13.8
14
2.800
175u3341
175u3055
175u3056
-
2.5
13.3
T4
37
9.0
11.1
12
3.200
175u3359
175u3061
175u3062
-
2.5
15.3
T4
45
8.0
9.1
9.5
4.200
-
175u3065
175u3066
-
4
20
T4
55
6.0
7.4
7.0
5.500
-
175u3070
175u3071
-
6
26
T4
75
4.0
5.4
5.5
7.000
-
-
-
175u3231
10
36
Table 8.31 T4, Horizontal Braking 10% Duty Cycle
Selection Guide
Design Guide
MG90O202
Danfoss A/S © Rev. 05/2014 All rights reserved.
57
8
8
Summary of Contents for VLT Brake Resistor MCE 101