8.2.5 VLT
®
AutomationDrive FC 301
10% duty cycle, horizontal braking, T2
FC 301
Horizontal braking 10% duty cycle
Frequency converter data
Brake resistor data
Installation
R
rec
[
Ω
]
P
br,cont.
[kW]
Danfoss part number
Cable
cross-
section
[mm
2
]
Thermo
relay
[A]
Mains
type
P
m
[kW]
R
min
[
Ω
]
R
br,nom
[
Ω
]
Wire IP54
Screw
terminal
IP21
Screw
terminal
IP65
Bolt
connection
IP20
T2
0.25
368
415.9
410
0.100
175u3004
-
-
-
1.5
0.5
T2
0.37
248
280.7
300
0.100
175u3006
-
-
-
1.5
0.6
T2
0.55
166
188.7
200
0.100
175u3011
-
-
-
1.5
0.7
T2
0.75
121
138.4
145
0.100
175u3016
-
-
-
1.5
0.8
T2
1.1
81.0
92.0
100
0.100
175u3021
-
-
-
1.5
0.9
T2
1.5
58.5
66.5
70
0.200
175u3026
-
-
-
1.5
1.6
T2
2.2
40.2
44.6
48
0.200
175u3031
-
-
-
1.5
1.9
T2
3
29.1
32.3
35
0.300
175u3325
-
-
-
1.5
2.7
T2
3.7
22.5
25.9
27
0.360
175u3326 175u3477 175u3478
-
1.5
3.5
T2
5.5
17.7
19.7
18
0.570
175u3327 175u3442 175u3441
-
1.5
5.3
T2
7.5
12.6
14.3
13
0.680
175u3328 175u3059 175u3060
-
1.5
6.8
T2
11
8.7
9.7
9
1.130
175u3329 175u3068 175u3069
-
2.5
10.5
T2
15
5.3
7.5
5.7
1.400
175u3330 175u3073 175u3074
-
4
15
T2
18.5
5.1
6.0
5.7
1.700
175u3331 175u3483 175u3484
-
4
16
T2
22
3.2
5.0
3.5
2.200
175u3332 175u3080 175u3081
-
6
24
T2
30
3.0
3.7
3.5
2.800
175u3333 175u3448 175u3447
-
10
27
T2
37
2.4
3.0
2.8
3.200
175u3334 175u3086 175u3087
-
16
32
Table 8.19 T2, Horizontal Braking 10% Duty Cycle
40% duty cycle, vertical braking, T2
FC 301
Vertical braking 40% duty cycle
Frequency converter data
Brake resistor data
Installation
R
rec
[
Ω
]
P
br,cont.
[kW]
Danfoss part number
Cable
cross-
section
[mm
2
]
Thermo
relay
[A]
Mains
type
P
m
[kW]
R
min
[
Ω
]
R
br,nom
[
Ω
]
Wire IP54
Screw
terminal
IP21
Screw
terminal
IP65
Bolt
connection
IP20
T2
0.25
368
415.9
410
0.100
175u3004
-
-
-
1.5
0.5
T2
0.37
248
280.7
300
0.200
175u3096
-
-
-
1.5
0.8
T2
0.55
166
188.7
200
0.200
175u3008
-
-
-
1.5
0.9
T2
0.75
121
138.4
145
0.300
175u3300
-
-
-
1.5
1.3
T2
1.1
81.0
92.0
100
0.450
175u3301
175u3402
175u3401
-
1.5
2
T2
1.5
58.5
66.5
70
0.570
175u3302
175u3404
175u3403
-
1.5
2.7
T2
2.2
40.2
44.6
48
0.960
175u3303
175u3406
175u3405
-
1.5
4.2
T2
3
29.1
32.3
35
1.130
175u3304
175u3408
175u3407
-
1.5
5.4
T2
3.7
22.5
25.9
27
1.400
175u3305
175u3410
175u3409
-
1.5
6.8
T2
5.5
17.7
19.7
18
2.200
175u3306
175u3412
175u3411
-
1.5
10.4
T2
7.5
12.6
14.3
13
3.200
175u3307
175u3414
175u3413
-
2.5
14.7
T2
11
8.7
9.7
9
5.500
-
175u3176
175u3177
-
4
23
T2
15
5.3
7.5
5.7
6.000
-
-
-
175u3233
10
33
T2
18.5
5.1
6.0
5.7
8.000
-
-
-
175u3234
10
38
T2
22
3.2
5.0
3.5
9.000
-
-
-
175u3235
16
51
T2
30
3.0
3.7
3.5
14.000
-
-
-
175u3224
25
63
T2
37
2.4
3.0
2.8
17.000
-
-
-
175u3227
35
78
Table 8.20 T2, Vertical Braking 40% Duty Cycle
Selection Guide
Design Guide
48
Danfoss A/S © Rev. 05/2014 All rights reserved.
MG90O202
8
8
Summary of Contents for VLT Brake Resistor MCE 101
Page 2: ......