Ordering type code frame size F
Description
Pos
Possible choice
Product group
1-3
Drive series
4-6
Power rating
8-10
500 - 1200 kW
Phases
11
Three phases (T)
Mains voltage
11-
12
T 5: 380-500 V AC
T 7: 525-690 V AC
Enclosure
13-
15
E21: IP 21/ NEMA Type 1
E54: IP 54/ NEMA Type 12
L2X: IP21/NEMA 1 with cabinet light & IEC 230V power outlet
L5X: IP54/NEMA 12 with cabinet light & IEC 230V power outlet
L2A: IP21/NEMA 1 with cabinet light & NAM 115V power outlet
L5A: IP54/NEMA 12 with cabinet light & NAM 115V power outlet
H21: IP21 with space heater and thermostat
H54: IP54 with space heater and thermostat
R2X: IP21/NEMA1 with space heater, thermostat, light & IEC 230V outlet
R5X: IP54/NEMA12 with space heater, thermostat, light & IEC 230V outlet
R2A: IP21/NEMA1 with space heater, thermostat, light, & NAM 115V outlet
R5A: IP54/NEMA12 with space heater, thermostat, light, & NAM 115V outlet
RFI filter
16-
17
H2: RFI filter, class A2 (standard)
H4: RFI filter, class A1
2, 3)
HE: RCD with Class A2 RFI filter
2)
HF: RCD with class A1 RFI filter
2, 3)
HG: IRM with Class A2 RFI filter
2)
HH: IRM with class A1 RFI filter
2, 3)
HJ: NAMUR terminals and class A2 RFI filter
1)
HK: NAMUR terminals with class A1 RFI filter
1, 2, 3)
HL: RCD with NAMUR terminals and class A2 RFI filter
1, 2)
HM: RCD with NAMUR terminals and class A1 RFI filter
1, 2, 3)
HN: IRM with NAMUR terminals and class A2 RFI filter
1, 2)
HP: IRM with NAMUR terminals and class A1 RFI filter
1, 2, 3)
Brake
18
B: Brake IGBT mounted
X: No brake IGBT
R: Regeneration terminals
M: IEC Emergency stop pushbutton (with Pilz safety relay)
4)
N: IEC Emergency stop pushbutton with brake IGBT and brake terminals
4)
P: IEC Emergency stop pushbutton with regeneration terminals
4)
Display
19
G: Graphical Local Control Panel LCP
Coating PCB
20
C: Coated PCB
Mains option
21
X: No mains option
3
2)
: Mains disconnect and Fuse
5
2)
: Mains disconnect, Fuse and Load sharing
7: Fuse
A: Fuse and Load sharing
D: Load sharing
E: Mains disconnect, contactor & fuses
2)
F: Mains circuit breaker, contactor & fuses
2)
G: Mains disconnect, contactor, loadsharing terminals & fuses
2)
H: Mains circuit breaker, contactor, loadsharing terminals & fuses
2)
J: Mains circuit breaker & fuses
2)
K: Mains circuit breaker, loadsharing terminals & fuses
2)
A options
29-30
AX: No options
A0: MCA 101 Profibus DP V1
A4: MCA 104 DeviceNet
AN: MCA 121 Ethernet IP
B options
31-32
BX: No option
BK: MCB 101 General purpose I/O option
BP: MCB 105 Relay option
BO:MCB 109 Analog I/O option
BY: MCO 101 Extended Cascade Control
C
0
options
33-34
CX: No options
C
1
options
35
X: No options
5: MCO 102 Advanced Cascade Control
C option software
36-37
XX: Standard software
D options
38-39
DX: No option
D0: DC backup
The various options are described further in this Design Guide.
4 How to Order
VLT
®
AQUA Drive Design Guide
94
MG.20.N5.02 - VLT
®
is a registered Danfoss trademark
4