FCM 300 Series
MG.03.B6.2G - VLT is a registered Danfoss trademark
Special functionsSpecial functionsSpecial functionsSpecial functionsSpecial functions
Serial communicationSerial communicationSerial communicationSerial communicationSerial communication
Parameters
Range/number
Function
of settings
Factory setting
Parameter No.
Preset reference 1
-100.00 % - +100.00 %
0.00 %
Parameter 215
Preset reference 2
-100.00 % - +100.00 %
0.00 %
Parameter 216
Catch up/slow down value
0.00 - 100.00 %
0.00 %
Parameter 219
Current limit for motor mode
Min.- max. limit in % of I
RATED
Max. limit
Parameter 221
Frequency bypass, bandwidth
0 (off) - 100 %
0 %
Parameter 229
Frequency bypass 1
0.0 - 132 Hz
0.0 Hz
Parameter 230
Frequency bypass 2
0.0 - 132 Hz
0.0 Hz
Parameter 231
Time out
1 -99 sec.
10 sec.
Parameter 317
Function after time out
Off/Stop and trip
Off
Parameter 318
P
ulse reference/feedback, max. freq.
100 - 70000 Hz
5000 Hz
Parameter 327
Terminal 1, analog input current
3
No operation
Parameter 331
Terminal 2, digital input
25
Reference
Parameter 332
Terminal 3, digital input
25
Reset
Parameter 333
Terminal 4, digital input
24
Start
Parameter 334
Terminal 5, digital input
23
Jog
Parameter 335
Terminal 1, min. scaling
0.0 - 20.0 mA
0.0 mA
Parameter 336
Terminal 1, max. scaling
0.0 - 20.0 mA
20.0 mA
Parameter 337
Terminal 2, min. scaling
0.0 - 10.0 V
0.0 V
Parameter 338
Terminal 2, max. scaling
0.0 - 10.0 V
10.0 V
Parameter 339
Output functions
21
No operation
Parameter 340
Brake function
Off/AC braking
Off
Parameter 400
Reset function
11
Manual reset
Parameter 405
Switching frequency
1.5 - 14.0 kHz
Unit dependent
Parameter 411
Variable switching frequency
3
Temp. dep. sw. freq.
Parameter 412
Overmodulation function
Off/On
On
Parameter 413
Minimum feedback
-100000 - FB
HIGH
0
Parameter 414
Maximum feedback
FB
LOW
- 100,000
1500
Parameter 415
Reference/feedback unit
42
%
Parameter 416
Process PID normal/inverse ctrl.
Normal/inverse
Normal
Parameter 437
Process PID anti windup
Disable/Enable
Enable
Parameter 438
Process PID start frequency
f
MIN
- f
MAX
f
MIN
Parameter 439
Process PID proportional gain
0.00 (off) - 10.00
0.01
Parameter 440
Process PID integral time
0.01 - 9999 sec. (off)
9999 sec.
Parameter 441
Process PID differentation time
0.00 (off) - 10.00 sec.
0.00 sec.
Parameter 442
Process PID different. gain limit
5 -50
5
Parameter 443
Process PID lowpass filter time
0.1 - 10.00 sec.
0.1 sec.
Parameter 444
Flying start
4
Disable
Parameter 445
Switching pattern
2
SFAVM
Parameter 446
Bus address
1 - 126
1
Parameter 500
Baudrate
300 - 9600 Baud/6
9600 Baud
Parameter 501
Coasting
4
Logic or
Parameter 502
Quick-stop
4
Logic or
Parameter 503
DC-brake
4
Logic or
Parameter 504
Start
4
Logic or
Parameter 505
Reversing
4
Logic or
Parameter 506
Selection of setup
4
Logic or
Parameter 507
Selection of speed
4
Logic or
Parameter 508
Bus jog 1
0.0 - f
MAX
10.0 Hz
Parameter 509
Bus jog 2
0.0 - f
MAX
10.0 Hz
Parameter 510
Telegram profile
Profidrive/FC Drive
FC Drive
Parameter 512
Bus time interval
1 sec.
Parameter 513
Bus time interval function
6
Off
Parameter 514
Inputs and OutputsInputs and OutputsInputs and OutputsInputs and OutputsInputs and Outputs
Standard Parameter Settings
■
19-3