Pa
r. No.
#
Para
mete
r descripti
on
Def
ault value
4-
se
t-
up
Cha
nge
duri
ng
op
era
-
tio
n
Conve
r-
sion inde
x
Type
8-0*
Gen
er
al Set
ti
n
g
s
8-
01
Contro
l S
ite
nu
ll
All se
t-
up
s
TRU
E
-
U
in
t8
8-
02
Contro
l S
ource
nu
ll
All se
t-
up
s
TRU
E
-
Ui
nt8
8-
03
Co
ntrol
Ti
meo
ut Time
Ex
pr
essio
nLimi
t
1 s
et-up
TR
UE
-1
Ui
nt32
8-
04
Contro
l T
imeou
t Fun
ct
ion
[0
] O
ff
1 s
et-up
TRU
E
-
Ui
nt8
8-05
En
d-o
f-Timeou
t
Fun
ct
ion
[1
] Resume
set
-up
1 s
et-
up
TRUE
-
U
in
t8
8-
06
Rese
t Co
ntrol
Timeo
ut
[0
]
Do
n
ot rese
t
All se
t-
up
s
TRU
E
-
Ui
nt8
8-
07
Diagnosis Trigge
r
[0
] Disa
ble
2 s
et-up
s
TRU
E
-
Ui
nt8
8-1*
Co
n
trol
Set
ti
n
gs
8-
10
Con
tr
ol Pr
of
ile
[0
] F
C
pr
of
ile
All se
t-
up
s
TRU
E
-
U
in
t8
8-
13
Configura
bl
e St
atu
s
Wo
rd STW
[1] Pro
fil
e De
fault
All se
t-
up
s
TRU
E
-
Ui
nt8
8-3*
FC Por
t S
et
ti
n
gs
8-
30
Proto
col
[0
] F
C
1 s
et-up
TRU
E
-
Ui
nt8
8-
31
Ad
dr
ess
Ex
pr
essionLimit
1 s
et-
up
TRUE
0
U
int
8
8-
32
Baud Rate
nu
ll
1 s
et-up
TRU
E
-
Ui
nt8
8-
33
Pa
rity /
S
to
p Bi
ts
nu
ll
1 se
t-
up
TRU
E
-
U
in
t8
8-
35
Mi
ni
mu
m Re
sp
on
se
D
ela
y
Ex
pr
essionLimit
1 s
et-up
TRU
E
-3
Ui
nt16
8-36
M
ax
imum Respo
nse
Del
ay
Ex
pr
essionLimi
t
1 s
et-
up
TRUE
-3
Ui
nt16
8-
37
M
ax
imum Inter-
Char
Del
ay
Ex
pr
essionLimit
1 s
et-up
TRU
E
-5
Ui
nt16
8-4*
Adv. P
rotocol
S
et.
8-
40
Tel
egr
am
S
ele
ct
io
n
[1] S
tandard
te
le
gr
am 1
2 s
et-up
s
TRU
E
-
Ui
nt8
8-
45
BT
M
Tr
an
sa
ct
io
n Co
mm
an
d
[0]
Of
f
All
se
t-
up
s
FA
LS
E
-
U
in
t8
8-
46
BTM
Transaction S
tatu
s
[0
] O
ff
All se
t-
up
s
TRU
E
-
Ui
nt8
8-
47
BTM
Timeout
60 s
1 s
et-up
FALSE
0
Ui
nt16
8-5*
Dig
it
al/
Bus
8-
50
Coasting Select
[3
] L
og
ic
O
R
All se
t-
up
s
TRU
E
-
U
in
t8
8-
52
DC
Brake
Se
le
ct
[3
] L
og
ic
O
R
All se
t-
up
s
TRU
E
-
Ui
nt8
8-
53
Star
t Sel
ect
[3
] L
og
ic
O
R
All
se
t-
up
s
TRU
E
-
U
in
t8
8-
54
Reve
rsin
g Sel
ect
nu
ll
All se
t-
up
s
TRU
E
-
Ui
nt8
8-
55
Se
t-up
S
el
ect
[3
] L
og
ic
O
R
All
se
t-
up
s
TRU
E
-
U
in
t8
8-
56
Pr
es
et
Re
fe
re
nc
e S
ele
ct
[3
] L
og
ic
O
R
All se
t-
up
s
TRU
E
-
Ui
nt8
8-7*
BACne
t
8-
70
BAC
ne
t De
vic
e
In
st
ance
1 N
/A
1 s
et-up
TRU
E
0
Ui
nt32
8-
72
M
S/
TP
M
ax
Maste
rs
12
7 N/
A
1 s
et-up
TR
UE
0
U
in
t8
8-
73
MS
/T
P Ma
x
In
fo
F
ra
m
es
1 N
/A
1 s
et-up
TRU
E
0
Ui
nt16
8-
74
"I
-A
m" Servi
ce
[0
] S
end at
power-
up
1
se
t-
up
TRUE
-
U
in
t8
8-
75
Initia
lisation Password
Ex
pr
essionLimit
1 s
et-up
TRU
E
0
Vi
sSt
r[
20]
8-8*
FC P
o
rt
D
iagn
o
sti
cs
8-
80
Bus Messa
ge
Count
0 N
/A
All se
t-
up
s
TRU
E
0
Ui
nt32
8-81
Bus Error Cou
nt
0 N
/A
All se
t-
up
s
TRU
E
0
U
in
t3
2
8-
82
Sla
ve M
essage
Cou
nt
0 N
/A
All se
t-
up
s
TRU
E
0
Ui
nt32
8-
83
Sl
av
e Erro
r
Count
0 N
/A
All se
t-
up
s
TRU
E
0
Ui
nt32
8-9*
B
u
s Jog / Fe
edbac
k
8-
90
Bus Jog
1 S
pe
ed
10
0 R
PM
All se
t-
up
s
TRU
E
67
U
in
t1
6
8-
91
Bus Jog
2 S
pe
ed
20
0 R
PM
All se
t-
up
s
TRU
E
67
Ui
nt16
8-
94
Bus Fee
db
ack 1
0 N
/A
1 se
t-
up
TRU
E
0
N
2
8-
95
Bus Feed
ba
ck 2
0 N
/A
1 s
et-up
TRU
E
0
N2
8-
96
Bus Fee
db
ack 3
0 N
/A
1 se
t-
up
TRU
E
0
N
2
4.1.9
8
-*
*
Com
m
unicat
ion and Options
4 Parameter Lists
ADAP-KOOL
®
Drive Programming Guide
234
MG.11.N1.02 - VLT
®
is a registered Danfoss trademark
4