Piranha HS-S0-06K Camera User Manual
03-032-20213-01
Teledyne DALSA
16
Frame Grabbers
The H S-Sx m od el cam eras (H SLink) are com p atible w ith the Xcelera -H S PX8
fram egrabber.
HSLink 6K and Frame Grabber Supplementary
Information
Teled yne DALSA d esigned and p ioneered the H SLink as a com p rehensive cam era-to-
fram e grabber com m u nication stand ard targeted at m achine vision ind u stry u se. The
H SLink 6K an d fram e grabber p rod u ct are based on the fu nd am ental cap abilities of th is
new interface.
We are w orking w ith ind u stry p artners to im p rove and to broad en the interface’s ap p eal
for the m achine vision in d u stry and as a resu lt exp ect that the original sp ecification w ill
change an d be im p roved . Ou r p rod u cts d elivered d u rin g this d raft sp ecification p h ase
w ill be field u p grad eable so that cu stom ers can gain the benefit from an ind u stry
ap p roved interface. The table below su m m arizes the m ajor fu nctions su p p orted w ith the
p rod u ct.
HSLINK Function
Current Comment
Cable Disconnect Recovery
N o
The cam eras w ill only prop erly lock to fram e
grabber w hen the cam era is tu rned on before
or after starting the d ata acqu isition p rogram .
Tu rn off the cam era w hen exiting a p rogram
that u ses the Fram e grabber.
Data Forw ard ing
Yes
Cu stom er m u st id entify the Master/ Slave
Fram e grabber d u ring the system
configu ration step . There is no Master/ Slave
com m u nication channel su p port.
Com m u nication Betw een FG
N o
This is the GMII com m and channel and w ill
enable au to enu m eration of slaves and d ata
resend requ ests from the slaves.
Vid eo Data Resend
N o
Master/ Slave com m and channel u sed for
error com m u nication from slave is not
available at this tim e. Can be field u p grad ed .
LED fu nctions
N o
GeniCam
N o
Use the ASCII serial com m and set for the
cam eras.
Trigger/ Direction Control
Yes
Area/ Line Scan Mod e
Yes
12 bit m od e
N o
Data w ill be p acked on the Link. This w ill
exceed the PCIx 8 Gen 1 band w id th.
Missed Trigger Flag
N o
DATA CRC Error Flag
Yes
CRC error cou nters available
H ead er Error Flag
Yes
H ead er error cou nter available
8b/ 10B Error cou nter
Yes
Enables BER calcu lation
Test Patterns
Yes
Good for system d ebu g
Data Lost Flag
N o
Ind icates m issing row s of inform ation
Cam era Data bu ffer overflow
N o
Id le Lock Lost
N o
Far end Reset
N o
Cm d Packet Failu re
N o