External Trigger Level-controlled Exposure
•
Also known as “Pulse Width Control” exposure. See the timing diagram below.
•
The external trigger edge initiates the exposure process. The active external trigger edge
can be selected as either the low-high or high-low transition.
•
No delay from active trigger edge to start of exposure. Note that the user must account
for the input opto-coupler electrical specifications (see "External Inputs" on page 113).
•
Exposure is stopped by the opposite edge on the trigger signal. Therefore the exposure
time is defined by the trigger pulse duration.
•
Supports "Reset Mode" on page 57 trigger timing only.
External Trigger Level-controlled Exposure Timing
54
•
Operational Reference
Genie Monochrome Series-GigE Vision Camera