TimestampCounter
RW
Always
ENUM
Internal Clock (1µs resolution) =
0
Input 1 = 1
Input 2 = 2
End of Readout = 3
SaveCameraConfigurationSelector
RW
N.conn
ENUM
Camera Configuration 1 = 1
LoadCameraConfigurationSelector
RW
N.conn
ENUM
Factory Default = 0
Camera Configuration 1 = 1
IPConfigurationMode
RW
N.acq
ENUM
DHCP/LLA mode = 0
Persistent IP mode = 1
NetworkConfigurationMode
RW
N.conn
ENUM
Automatic = 0
Manual = 1
Feature Type INT32
The feature list for type INT32 has an additional column 'Exponent' which defines the
feature's native unit. This exponent value is used as a unit multiplier so that the feature
value is expressed as an integer, not a decimal number.
•
As an example from the following table, the Genie frame rate is 60000 with an exponent
of 3. Therefore the frame rate native unit is mHz. The current value shown –
60000 mHz, is actually 60.000 Hz.
Feature Name
(type INT32)
Acces
s
Write
mode
Exponent
Sample
Value
Boundaries
DeviceMaxThroughput
RO
Invalid EXP10: 0
1843200
0
min=0, max=0, inc=0
SensorWidth
RO
Invalid EXP10: 0
640
1 to sensor width
SensorHeight
RO
Invalid EXP10: 0
480
1 to sensor height
FrameRate (mHz)
RW
Always EXP10: 3
60000
100 to camera max
BlackLevel
RW
Always EXP10: 0
0
min= -128, max=127,
inc=1
Gain
RW
Always EXP10: 1
0
min= -60, max=120,
inc=1
ExposureTime (μS)
RW
Always EXP10: 6
16384
min=22, max=16000000,
inc=1
TriggerDelayToIntegration
(μS)
RW
N.acq EXP10: 6
0
min=0, max=xxx, inc=1
FramesPerTrigger
RW
Always EXP10: 0
1
min=1, max=32767,
inc=1
LUTNumberEntries
RO
Invalid EXP10: 0
256
min=1, max=65536,
inc=1
DebounceInput_1 (μS)
RW
Always EXP10: 6
10
min=1, max=255, inc=1
DebounceInput_2 (μS)
RW
Always EXP10: 6
10
min=1, max=255, inc=1
PulseDelayOutput_1 (μS)
RW
Always EXP10: 6
0
min=0, max=16777215,
inc=1
PulseDurationOutput_1 (μS)
RW
Always EXP10: 6
0
min=100,
max=16777215, inc=1
PulseDelayOutput_2 (μS)
RW
Always EXP10: 6
0
min=0, max=16777215,
inc=1
86
•
Operational Reference