Open and Close Output Settings
You can open and close the output circuit using software rather than hardware events, to
control external devices. To control the output setting with Sapera LT see "Output Control
via Sapera LT or GigE Vision Compliant Applications" on page 67.
Strobe On Start of Exposure Event Mode
The Strobe On Start of Exposure event mode is used when controlling a strobe light using
the Genie output pin. The exposure delay parameter is specified using the Sensor
Parameters tab Exposure Control setting.
For Synchronous mode, the exposure start timing is aligned to the line period of the sensor.
This can delay the start of exposure by an amount of up to 31.77µs for the Genie M640. For
more information on exposure synchronous time see "Exposure Controls" on page 51.
Genie Monochrome Series-GigE Vision Camera
Operational Reference
•
63