50
•
Operational Reference
Falcon™ 4
-CLHS Series
Device Counter and Timer Control Feature Descriptions
Display Name
Feature & Values
Description
Device
Version
& View
Counter Selector
counterSelector
Selects the counter to configure.
1.00
Beginner
DFNC
Counter 1
Counter1 Select counter 1
Counter Mode
counterMode
Selects the counter mode. The selected Counter is either
Active or Disabled. When Disabled, the Counter can be
configured.
1.00
Beginner
DFNC
Off
Off The selected Counter is Disabled
Active
Active The selected Counter is Enabled
Counter Status
counterStatus
Returns the current state of the counter.
1.00
Beginner
DFNC
Counter Idle
CounterIdle The counter is idle.
The counterStartSource feature is set to off.
Counter Trigger Wait
CounterTriggerWait The counter is waiting for a start trigger.
Counter Active
CounterActive The counter is counting for the specified duration.
Counter Completed
CounterCompleted The counter reached the CounterDuration count.
Counter Overflow
CounterOverflow The counter reached its maximum possible count.
Counter Pause
CounterPause The counter is paused.
1.00
Beginner
DFNC
counterStartSource
Select the counter start source. Counter increments from 0
to the value of the counterDuration feature.
1.00
Beginner
DFNC
No Source
Off Counter is stopped.
Exposure Start
ExposureStart Counter starts on the reception of the Exposure Start event
Exposure End
ExposureEnd Counter starts on the reception of the Exposure End event.
Readout Start
ReadoutStart Counter starts on the reception of the Readout Start event.
Readout End
ReadoutEnd Counter starts on the reception of the Readout End event.
Frame Start
FrameStart Counter starts on the reception of the Frame Start event.
Valid Frame Trigger
ValidFrameTrigger Counter starts on the reception of the Valid Frame Trigger.
Invalid Frame Trigger
InvalidFrameTrigger Counter starts on the reception of the Invalid Frame
Trigger.
Line 1
Line1 Counter starts on the specified transitions on Line 1
See Input Signals Electrical Specifications.
Line 2
Line2 Counter starts on the specified transitions on Line 2
CLHS In
LinkTrigger0 Counter starts on the transitions of LinkTrigger0 (based on
the counterIncrementalLineActivation feature setting).
Timer 1 End
Timer1End Counter starts on the reception of the Timer 1 End event.
Counter 1 End
Counter1End Counter starts on the reception of the Counter 1 End event.
Counter Start Line
Activation
counterStartLineActivation
Selects the activation mode of the input line trigger which
starts the counter. This is only applicable when the
counterStartSource feature selects a physical Line.
1.00
Beginner
DFNC
Rising Edge
RisingEdge Starts counting on rising edge of the selected Line.
Falling Edge
FallingEdge Starts counting on falling edge of the selected Line.
Any Edge
AnyEdge Starts counting on the falling or rising edge of the selected
Line.
Summary of Contents for Falcon 4-CLHS Series
Page 14: ...12 Falcon4 CLHS Specifications Falcon 4 CLHS Series Effective Quantum Efficiency ...
Page 87: ...Falcon 4 CLHS Series Additional Reference Information 85 Cable Assembly G5 AIOC BLUNT2M ...
Page 88: ...86 Additional Reference Information Falcon 4 CLHS Series ...
Page 89: ...Falcon 4 CLHS Series Additional Reference Information 87 Generic Power Supply with no I O ...