Falcon™ 4
-CLHS Series
Operational Reference
•
31
Trigger Overlap: Feature Details
The Trigger Overlap feature defines how the Falcon4-CLHS handles triggers that might occur more
frequently than the Frame Active period (an exposure plus readout period). If TriggerOverlap =
OFF, then triggers received before the end of the Frame Active period are ignored. Other
TriggerOverlap values are dependent on the camera model and sensor used.
•
TriggerOverlap = Off
•
No trigger overlap is permitted.
Diagram Conditions:
•
TriggerMode = On
•
ExposureMode = Timed
•
TriggerActivation = RisingEdge
•
TriggerDelay = 0
•
TriggerSelector = FrameStart
•
ExposureAlignment = Synchronous
Trigger Input
Trigger Exclusion Period
Exposure 1
Readout 1
Frame 1 Active period
Trigger Exclusion Period
Exposure 2
Readout 2
Frame 2 Active period
Frame Exposure
Frame Readout
TriggerOverlap=Off
TriggerOverlap = ReadOut
•
Trigger is accepted at the beginning of the frame Readout. The
“End of Exposure to Start of
Readout” time is sensor dependent.
Diagram Conditions:
•
TriggerMode = On
•
ExposureMode = Timed
•
TriggerActivation = RisingEdge
•
TriggerDelay = 0
•
TriggerSelector = FrameStart
•
ExposureAlignment = Synchronous
Trigger Input
Trigger Exclusion Period
Exposure 1
Readout 1
Frame 1 Active period
Exposure 2
Readout 2
Frame 2 Active period
Frame Exposure
Frame Readout
TriggerOverlap=Readout
Trigger Exclusion Period
End of Exposure
to Start of Readout
End of Exposure
to Start of Readout
Summary of Contents for Falcon 4-CLHS Series
Page 14: ...12 Falcon4 CLHS Specifications Falcon 4 CLHS Series Effective Quantum Efficiency ...
Page 87: ...Falcon 4 CLHS Series Additional Reference Information 85 Cable Assembly G5 AIOC BLUNT2M ...
Page 88: ...86 Additional Reference Information Falcon 4 CLHS Series ...
Page 89: ...Falcon 4 CLHS Series Additional Reference Information 87 Generic Power Supply with no I O ...