Falcon™ 4
-CLHS Series
Operational Reference
•
51
Counter Incremental
Source
counterIncrementalSource
Select the event source which increments the counter. The
Event Control section
provides details and timing diagrams
for the supported events.
1.00
Beginner
DFNC
Off
Off Counter is stopped.
Exposure Start
ExposureStart Counts the number of Exposure Start events.
ExposureEnd
ExposureEnd Counts the number of Exposure End events.
Readout Start
ReadoutStart Counts the number of Readout Start events.
Readout End
ReadoutEnd Counts the number of Readout End events.
Frame Start
FrameStart Counts the number of Frame Start events.
Valid Frame Trigger
ValidFrameTrigger Counts the number of Valid Frame Triggers.
Frame Burst
FrameBurstEnd Counts the number of multi-frame end triggers.
CLHS In
LinkTrigger0 Counts the number of transitions on LinkTrigger0.
Line 1
Line1 Counts the number of transitions on Line 1 (based on the
counterIncrementalLineActivation feature setting)
See Input Signals Electrical Specifications.
Line 2
Line2 Counts the number of transitions on Line 2 (based on the
counterIncrementalLineActivation feature setting)
Invalid Frame Trigger
InvalidFrameTrigger Counts the number of rejected frame triggers.
Internal Clock
InternalClock The counter increments on each microsecond tick of the
device internal Clock.
Timer 1 End
Timer1End Counts the number of Timer 1 End events.
Counter Incremental Line
Activation
counterIncrementalLineActivation
Selects the counter signal activation mode. The counter
increments on the specified signal edge or level.
1.00
Beginner
DFNC
Rising Edge
RisingEdge Increment the counter on the rising edge of the selected
I/O Line.
Falling Edge
FallingEdge Increment the counter on the falling edge of the selected
I/O Line.
Any Edge
AnyEdge Increment the counter on the falling or rising edge of the
selected I/O Line.
Counter Duration
counterDuration
Sets the duration (or number of events) before the
CounterEnd event is generated.
1.00
Beginner
DFNC
counterResetSource
Selects the signal source to reset the counter. After a reset
the counter waits for the next countStartSource signal or
event.
1.00
Beginner
DFNC
Off
Off Reset on reception of the Reset Icommand.
Exposure Start
ExposureStart Reset on reception of the Exposure Start event.
Exposure End
ExposureEnd Reset on reception of the Exposure End event.
Readout Start
ReadoutStart Reset the counter on the reception of the Readout Start
event.
Readout End
ReadoutEnd Reset the counter on the reception of the Readout End
event.
Frame Start
FrameStart Reset on reception of the Frame Start.
Valid Frame Trigger
ValidFrameTrigger Reset on reception of the Valid Frame Trigger.
Invalid Frame Trigger
InvalidFrameTrigger Reset on reception of the Invalid Frame Trigger.
FrameBurst End Trigger
FrameBurstEnd Reset on reception of the Frame Burst end.
Line 1
Line1 Reset counter on the specified transition on line 1.
See Input Signals Electrical Specifications.
Line 2
Line2 Reset counter on the specified transition on line 2.
CLHS In
Link0Trigger Reset on reception of CLHS In (Link0Trigger).
Timer 1 End
Timer1End Reset on reception of the Timer End.
Counter 1 End
Counter1End Reset on the reception of the Counter end.
Summary of Contents for Falcon 4-CLHS Series
Page 14: ...12 Falcon4 CLHS Specifications Falcon 4 CLHS Series Effective Quantum Efficiency ...
Page 87: ...Falcon 4 CLHS Series Additional Reference Information 85 Cable Assembly G5 AIOC BLUNT2M ...
Page 88: ...86 Additional Reference Information Falcon 4 CLHS Series ...
Page 89: ...Falcon 4 CLHS Series Additional Reference Information 87 Generic Power Supply with no I O ...