Falcon™ 4
-CLHS Series
Technical Specifications
•
71
External Output AC Timing Characteristics
The graphic below defines the test conditions used to measure the Falcon4 external output AC
characteristics, as detailed in the table that follows.
t
t
Output Control Signal
Output
100%
90%
10%
t
d1
t
ris e
t
fall
t
d2
Output
Out put Common Power
R
Load
Control
Signal
Camera
Opto-coupled Output:
AC Characteristics
Note: All measurements subject to some rounding.
The following tables describes GPO 1 and GPO 2 when the load is connected to a user-provided
ground. Test conditions are with front plate temperature ~62C, FPGA ~85C.
Output
Common Power
Output
R
load
t
d1 (
µs)
t
rise (
µs)
t
d2 (
µs)
t
fall (
µs)
V
out (
V)
Current
Test (ohm)
Leading
Delay
Rise
Time
Trailing
Delay
Fall Time
3V
8 mA
240
0.459
3
11
20.41
2.17
12ma
144
0.6
6.95
4.4
20
1.75
16 mA
40
0.6
11
1
12.9
0.559
5V
8 mA
523
0.469
2.64
12
22
4.24
16 mA
159
0.485
7.52
2.55
12
2.57
24 mA
69
0.64
7.52
1
8.42
1.69
12V
8 mA
1400
0.52
3.28
10.6
25.64
11.23
16 mA
595
0.52
3.28
4.12
13.86
9.61
24 mA
360
0.531
3.76
2.48
13.8
8.72
24V
8 mA
2907
0.541
1.63
22.8
37.8
23.31
16 mA
1346
0.556
2.2
7.4
18.32
21.58
24 mA
861
0.567
2.5
6.61
12.93
20.72
Summary of Contents for Falcon 4-CLHS Series
Page 14: ...12 Falcon4 CLHS Specifications Falcon 4 CLHS Series Effective Quantum Efficiency ...
Page 87: ...Falcon 4 CLHS Series Additional Reference Information 85 Cable Assembly G5 AIOC BLUNT2M ...
Page 88: ...86 Additional Reference Information Falcon 4 CLHS Series ...
Page 89: ...Falcon 4 CLHS Series Additional Reference Information 87 Generic Power Supply with no I O ...