9
Environmental Conditions
Operating Temperature
(
at camera front plate
)
All Models: -20°C to +50°C (-4°F to +122°F)
Any metallic camera mounting provides
heat-sinking therefor reducing the internal temperature.
Operating Relative Humidity
5% to 90% non-condensing.
Storage
-40°C to +80°C (-4°F to +176°F) temperature at 20% to 80% non-condensing
relative humidity.
Conformity
GenIcam compliant
CE, FCC, RoHS, KC
EU RoHS2, EU REACH, China RoHS2
IP Rating
IEC60529 IP40
(Protected against foreign object of 1 mm diameter, no protection against water.)
Sensor Cosmetic Specifications
After Factory Calibration and/or Corrections are applied (if applicable
—
dependent on sensor)
Blemish Specifications
Maximum Number of
Defects
Blemish Description
Hot/Dead Pixel defects
Typical 0.0025%
Max 0.005%
Any pixel that deviates by ±20% from the average of
neighboring pixels at 50% saturation including pixel stuck at 0
and maximum saturated value.
Spot defects
none
Grouping of more than 8 pixel defects within a sub-area of 3x3
pixels, to a maximum spot size of 7x7 pixels.
Clusters defects
none
Grouping of more than 5 single pixel defects in a 3x3 kernel.
Column defects
none
Vertical grouping of more than 10 contiguous pixel defects
along a single column.
Row defects
none
Horizontal grouping of more than 10 contiguous pixel defects
along a single row.
•
Test conditions
•
Nominal light = illumination at 50% of saturation
•
Temperature of camera is 45°C
•
At exposures lower than 0.25 seconds
•
At nominal sensor gain (1x)
Summary of Contents for Falcon 4-CLHS Series
Page 14: ...12 Falcon4 CLHS Specifications Falcon 4 CLHS Series Effective Quantum Efficiency ...
Page 87: ...Falcon 4 CLHS Series Additional Reference Information 85 Cable Assembly G5 AIOC BLUNT2M ...
Page 88: ...86 Additional Reference Information Falcon 4 CLHS Series ...
Page 89: ...Falcon 4 CLHS Series Additional Reference Information 87 Generic Power Supply with no I O ...