70
•
Technical Specifications
Falcon™ 4
-CLHS Series
External Inputs: Using a Balanced Driver
•
Warning: Only one External Signal can be used (input 1 or input 2).
RS-422
Compatible
Transmitter
10
9
8
7
6
5
4
3
2
1
Camera IO
Interface
Only one Input can be used
in this configuration.
!
External Signal
( Common Ground )
( Input 1 )
( Input 2 )
Output Signals Electrical Specifications
External Outputs Block Diagram
Protection
Current
Limiter
Protection
Current
Limiter
Output 2 (pin 8)
Output 1 (pin 6)
Output Common Power
(pin 4)
External Output Details and DC Characteristics
•
Programmable output mode such as strobe, event notification, etc
(see
feature)
•
Outputs are open on power-up with the default factory settings
•
A software reset will not reset the outputs to the open state if the outputs are closed
•
A user setup configured to load on boot will not reset the outputs to the open state if the
outputs are closed
•
No output signal glitch on power-up or polarity reversal
•
Typical
Operating Common Power Voltage Range: +3V to 28Vdc at 24mA
•
Maximum
Common Power Voltage Range : ±30Vdc
•
Maximum
Output Current: 36mA