Ø
Set the
Pre-Event time
(see above).
Ø
Configure
Private Zones
if required (see chapter
Basic configuration
).
Ø
Activate / configure the
Timer
if required (see chapter
Basic configuration
).
Ø
Activate the
Use Database
option if required.
Ø
Set the
Options
for contact recording.
Ø
Set the
Contact Recording Duration
if required.
Ø
Confirm with
OK
.
Normal Single
A contact triggers the recording of an individual picture.
Normal sequencer
The recording is triggered by the contact switching. It continues until the contact is released
again.
Start
The recording is triggered by the contact switching. The recording is stopped by an opposite
contact function (
Stop recording (Contact recording mode)
) or
Stop recording camera
(Contact recording mode)
).
Timer
The recording is started by the contact switching. Recording is stopped after the
Contact
Recording Duration
expired.
Toggle
The recording is triggered by the contact switching. It is stopped again by the same contact
switching again.
Mark
A marker (index) will be saved to the track when the contact is triggered. While playing back
theses markings can be searched (
index search
and
extended search
).
NOTE
The options
Event
and
Save
are not relevant in the
Contact
recording mode.
8.5
Video quality
Note that for technical reasons it is not possible to use every setting combination. There
are dependencies between the single settings. In addition they depend on the number of
channels (cameras) used, the recorder model and the video standard (PAL/NTSC).
Incorrect configurations will be compensated by automatically adjusting of the values. In some
cases the track size has to be reduced or the number of available channels adjusted.
8.5.1
Manual and automatic mode
Recording modes with video quality switching are available in these track modes. In this
case the following settings have to be made on the tab
Quality
. The procedure is the same