DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS
91
Dallmeier electronic
12.4
Functions
Functions
Explanantion
None
No function selected.
Shut down recorder
The recorder will be shut down without taking further
conditions into account.
Start alarm
This function activates the alarm state of the recorder.
The alarm duration can be set via
Setup
>
System
>
Options
>
Alarm Duration
.
Stop alarm
The recorder is in alarm state. The contact function
Stop
alarm
allows the alarm to be stopped before the end of
the alarm duration.
After stopping the alarm state, the secure tracks are saved
and new secure tracks created. The tracks are locked and
must be released separately.
Save Secure-Tracks (all)
Active recording into the secure tracks is stopped. The
secure tracks are saved. Recording is continued in new
secure tracks.
Activate Sequencer
The recorder will automatically switch to sequencer /
live- mode, 1x1 split. If cameras are defined for sequen
-
cer mode their live images will be displayed one after
another.
Extend alarm
The recorder is in alarm state. If the
Extend alarm
contact
function is triggered before the end of the alarm duration,
the alarm state will be extended indefinitely (or until the
corresponding track is full).
The alarm state can then only be stopped by the
Stop
alarm
contact function.
Delete alarm
The last alarm state will be canceled. Saved secure tracks
will be deleted. Locked tracks will be released again and
the images of the track will be deleted.
Send message with value
This contact function causes a message to be sent to the
alarm host. A binary value can be set in the
Contact Para-
meter
dialog. This value is sent together with the message
and can be freely interpreted by the alarm host.
Start recording
(recording mode contact)
This function stops each recording that is still active (timer
can be expired) that was triggered by
Start recording
(recording mode Contact)
.
Which camera is relevant is defined in the
Contact
Parameter
dialog.
Stop recording
(recording mode contact)
This function stops each recording that is still active (timer
can be expired) that was triggered by
Start recording
(recording mode Contact)
.
Which camera is relevant is defined in the
Contact
Parameter
dialog.
Quit pause of all alarm-hosts
This contact function allows to deactivate all configured
and activated alarm hosts. No messages are sent to
the alarm hosts until the
Quit pause of all alarm-hosts
contact function is triggered.