Matrix PS System Installation and Commissioning Guide
|
177
Dali Wireless Proprietary and Confidential | DW-MAN-036 Rev 06
To achieve the appropriate DL output power at the remote:
1. Select the host in the system tree, and click
to display the Band Information
view.
2. Change
DL Input Maximum Power
to be the power expected at the input to the
system. This value should have already been configured as described in
Maximum DL Input Power & Low Power Thresholds
. Adjust if necessary.
3. In the system tree, select the remote connected to the host, and click
to display
the band information view.
4. Enter an attenuation value in the
DL Output Attenuation
field to lower the DL
output power at the remote to adjust the gain to meet FCC guidelines (see below).
Wait 6 to 10 seconds for the EMS to update the RF power measurements.
15.3.1.1
Adjusting Gain to Me e t FCC S ig nal B ooste r Guide line s
In general, the ERP of the output noise within the pass band should not exceed the
level of -43 dBm in 10 kHz measurement bandwidth. The ERP of the output noise
outside of the passband by more than 1 MHz should not exceed the level of -70 dBm in
10 kHz measurement bandwidth. The ERP of intermodulation products should not
exceed -30 dBm in 10 kHz measurement bandwidth.