14.3.3
Clearing Alarms
Non-critical alarms are cleared automatically when the alarm condition is resolved. Critical
alarms require a user action to clear, such as re-activating an RF module or acknowledging
a missing unit.
Major and Critical alarms can resolve to Minor alarms, which do not impact commissioning
or affect continued service.
14.3.4
Resolving Critical Alarms
For Critical alarms caused by a missing unit, see
Managing Missing Units, RF Modules and
For Critical alarms that result in a deactivated the RF path, a red
Failed
RF Signal Path is
displayed in the Band Information view.
To clear a Critical alarm on the RF signal path:
1. Click
to display the Band Information view.
2. Click
Failed
to place the RF module in Standby.
3. Resolve the problem causing the alarm, and then click
Standby
to re-activate the RF
path. If the Failed status persists, contact Dali Customer Service.
14.4
Managing Missing Units, RF Modules and Optical
Ports
In addition to reviewing alarms, you need to verify that the system tree displays all the
installed RF modules, optical ports, hdHost PS units, and remotes.
If an installed device does not appear in the system tree:
Wait 6 to 10 seconds for the EMS to update the system tree.