xii
|
Dali Matrix PS System Installation and Commissioning Guide
Dali Wireless Proprietary and Confidential | DW-MAN-036 Rev 06
The highest expected output power is 33.2 dBm at 937.5MHz. For an output level of 33.2 dBm with
an indoor antenna gain of 3 dBi, the EIRP is 36.2 dBm.
The maximum power density safe exposure level for general population/uncontrolled exposure of
30 minutes for the frequency of 937.5 MHz is 0.625 mW/cm
2
.
Conducted Output
Power (dBm)
Max Antenna
Gain (dBi)
Max EIRP
(mW)
Power Density Limit
Allowed (mW/cm²)
Safe Distance
(cm)
33.2
3
4169
0. 625
24
As shown above, the minimum s a f e distance where the MPE limit is reached is 24 cm from
the unit with a 3 dBi antenna and no distribution loss.
If the antenna will be positioned closer to end users than 24 cm, then the installer must calculate
the safe distance for a given installation using the formulas provided.
TYPE 2 CHASSIS
Intermodulation
hd33 P S Q uad B and Dow nlink
450 MHz, 700 MHz, 800 MHz, 900 MHz band, Mode A (2W)
Example: 6 dB of minimum distribution loss when 2-carrier composite power is 33 dBm