Matrix PS System Installation and Commissioning Guide
|
169
Dali Wireless Proprietary and Confidential | DW-MAN-036 Rev 06
To make an RF module Available:
1. In the Configuration view
, click the
Unavailable
button for the RF module.
2. Wait 6 to 10 seconds until the button changes to blue
Available.
An RF module that has returned to Available is not Active. To
Activate the RF module, open the Band Information view and click
Standby. Wait 6 to 10 seconds until the button changes to Active.
14.5
Naming Units
At the start of commissioning, the system tree lists system controllers, hosts and remotes
without custom names or identifiers. Create names for each unit that identify the type of
unit, location or owner, band or frequency.
All name fields are limited to 31 characters.
14.5.1
Naming System Controllers
Give the system controller a name that identifies the unit type or location.
To enter a name for each unit:
1. Select the system controller in the system tree, and click
to display the Unit
Information view.
2. In the Unit Name field, e
nter a name that describes the unit’s location, either the
location in the rack or a geographical location.
14.5.2
Naming Host Units and RF Modules
Give the host units names that identify the unit type and location. Give the host RF modules
names that reflect the band frequency or operator.
To enter a name for a host unit and band:
1. Select the host in the system tree, and click
to display the Unit Information view.