14.4.3
Missing Optical Ports or SFPs
Optical ports or SFPs that are not responding also change status to Missing and cause a
Critical alarm. To clear a missing optical port alarm, click
Remove
.
14.4.4
Unavailable and Available RF Modules
If you don’t want to display a RF module in the EMS, you can hide, or disable the module
by making it Unavailable. When an RF module is Unavailable, its alarms are hidden and
the module is removed from the system tree and slot view.
Use the Unavailable option to hide an RF module when you are aware of an issue and
don’t need to see the associated major and critical alarms filling the Alarm Summary.
Only RF modules with Missing, Standby, or Fail status can be made Unavailable.
To make an RF module Unavailable:
1. Click
to display the Band Information view.
2. If the RF module is not already in Standby or Failed status, place the module in
3. Click
to display the Configuration view.
4. In the Configuration view, click the blue
Available
button for the RF module. Wait 6 to
10 seconds until the button changes to blue Unavailable.
5. If the button is dimmed and
can’t be clicked, it means the RF module is Active. Only RF
modules with Missing, Standby or Failed status can be made Unavailable.