45
MAN# 650814
WARN OUT: Will display a list of items that allow setting to either ON or OFF. An ON
setting means the associated warning violation will trigger the WARN terminal on the
Control Box. This terminal can also activate reverse lights when using a GSS-3000 or BIM-
01.
Note: When using this terminal for reverse lights, all other warnings will
automaticall
y be set to “OFF”.
Note: Regardless of the WARN OUT setting, a reading violation of a preset warning
level will illuminate the associated indicator on the Instrument Cluster, and also
indicate the violation in the Message Area.
The available warning violations include: BIM CH 1-16 (where each installed/configured
BIM accessory has an assigned channel #. If the BIM detects a violation, the GRAFIX will
report the warning), TACH, WATER, OIL, VOLTS, FUEL, EX+, EX-, REVERSE, and BACK.
WARN AUDIO: A list of the parameters associated to the internal audio tone will be
displayed: BUZZER SET, BUZZER STYLE, BUZZER VOL, BUZZER TONE, SPD CNT
VOL, and BACK. Rotate the Control Knob to the desired item, tap to select
o
BUZZER SET: Allows the user enable or disable with an ON/OFF setting - whether
the audible tone will be heard for the possible warning violations: BIM CH 1-16
(where each installed/configured BIM accessory has an assigned channel #. If the
BIM detects a violation, the GRAFIX will report the warning), TACH, WATER, OIL,
VOLTS, FUEL, EX+, and EX-.
o
BUZZER STYLE: Is a selection (0-10) of various types of audible pulses, of which
the user can select the most pleasing or what is most audible for their installation.
With the BUZZER VOL set to something other than 0 (i.e. volume not off), cycle
through the settings, tap to select
o
BUZZER VOL: Sets the volume in range of 0(off) to 10(max), tap to select
o
BUZZER TONE: Is a list of 3 differing tones (TONE 1
– 3). With the BUZZER VOL
set to something other than 0 (i.e. volume not off), cycle through the settings, tap to
select
o
SPD CNT VOL: The buzzer volume can be set to increase as measured speed
increases. The available settings are OFF, LOW, MID, HIGH, and BACK. Rotate to
the desired setting, tap to select
o
BACK: Will exit Warn audio sub-menu
WARN LED: The Warning LED feature is another method of notification to the user that a
system reading has violated a preset condition and needs attention. When Warn LED is
selected a list of system readings is displayed, and each can be enabled or disabled: BIM
CH 1-16 (where each installed/configured BIM accessory has an assigned channel #. If the
BIM detects a violation, the GRAFIX will report the warning), TACH, WATER, OIL, VOLTS,
FUEL, EX+, and EX-.
If the WARN LED is enabled for a specific system reading and a warning condition(fault) is
encountered, a red LED on the Instrument Cluster
will flash 3 times and a ‘warning box’ will
be displayed in the menu box location. This warning box will indicate what the warning is
and give the user the following 2 options.
TAP: ACCEPT
– This is acknowledgement that the warning has occurred. With a tap,
the warning box will be cleared and the LED immediately turned off, and will not reoccur
d
uring this error ‘instance’. With this ‘tap’, the warning will remain in the Message Area.
If a MENU is accessed and then exited a
ny time there is an ‘accepted’ warning, the
above warning box and flash sequence will repeat.