[9]
MAN #650832
Quick tips:
While the BIM is operating, the dot in the upper left corner of the display will indicate the status. On steady indicates it is
powered up but not receiving any BIM bus activity. Flashing indicates it is communicating on the BIM bus.
If the display shows “
” then it is scanning to try and communicate with the EFI system bus but cannot get an answer.
To see the sensor and channel status on the BIM display, press and hold the switch. The display will cycle through
several screens. The first will show the bus
type (“
” Holley EFI). The next screens will indicate which (if any) extended
data is available: “
” for intake/manifold temp, “
” for engine oil pressure.
Troubleshooting guide:
Problem
Possible cause
Solution
BIM will not light up at all
•
PWR wire does not have power.
•
Connect to a different ground location
•
Power/data harness is damaged.
•
Module is damaged.
•
Connect to a location that has +12V key-on
power.
•
Inspect harness and repair or replace.
•
Return for service. (See Instructions below)
BIM display is scanning “
”
•
EFI adapter harness is not connected
•
The EFI system is not compatible
•
The EFI is not powered on.
•
The EFI CAN is not configured to “Racepak”
•
Connect the appropriate harness to the EFI
CAN.
•
Verify compatibility.
•
Verify EFI system is powered on.
•
Verify CAN settings within EFI software.
•
If connected to Dominator, HP or Terminator verify
is set to
in the BIMs setup menu
BIM has a steady dot lit
•
Interface cable is not connected
•
Interface cable is loose.
•
On VHX systems, the BIM display for this is
disabled.
•
Connect the supplied data cable between the
BIM unit and the instrument system control box.
•
Make sure both ends of the cable are seated.
•
Follow instructions in VHX manual to enable
the BIM display screen.
BIM display shows
“
:
”
•
Data cable is damaged.
•
Another module on the bus is damaged or
connected improperly.
•
Inspect and replace the data cable.
•
Inspect other modules on the bus.