Dakota Digital BIM-01-2-HSN2 Quick Start Manual Download Page 3

 

[3] 

 

MAN #650832 

Display Setup 

VFD and VHX systems will add extra readings to the message displays under the tach. 
HDX and RTX need a group screen configured to show additional information such as Boost or Intake temp

 

 

Setting up the display system will configure the instrument control box to read each input from either the terminals or 
through the BIM cable from the Bus Interface Module. 
The BIM menu of the display will not find the BIM-01-2-HLLY, but will find specific channels for Fuel Pressure and Air/Fuel 
Ratio. 
 
There is no Check Engine option for the BIM-01-2-HLLY to pick up. 
 
The following settings are for the basic information to be displayed with data from the BIM module. 
Extra data that might be sent such as Intake Air Temp, Fuel Pressure, Air/Fuel Ratio or Boost, can be brought up in the 
message centers of the VFD3 and VHX system by toggling SW2 in normal operation of the vehicle.  Similar data that 
might be present will not automatically be shown in the HDX and RTX systems.  That extra information must be placed in 
a group screen of your choice, in the HDX and RTX setup.  
 

Display data usage 

The following readings can each be used in place of dedicated sending units to the instrument system control box. These 
are individually selectable in the display system instrument setup menus. 
 

VFD3, and VFD3X setup:

  

**Only VFD3/3X systems with a plastic case, support adding BIMs** 
 
Entering the VFD3 setup is done by holding SW1 (I) and tur

ning the ignition to “on”, or “acc”. 

Once in setup, one can move between 

speed

tach

volt

water

, etc

…. by tapping SW1 (I) 

If you are setting multiple items, once done with one section you will automatically move onto the next item. 

 
Obtaining RPM from the BIM-01-2-HLLY 

 

Hold the SW1 switch from the instrument system control box while turning the key on. 

o

 

The speed display should show 



 and the message display should show 

SETUP

 

Release SW1.  Tap SW1 until 



 and 

TACH

 are displayed. 

 

Press and hold SW1 for at least 3 seconds, until 



 

changes to “-”. The displays should show 



 and 

T CAL

 

Press and hold SW1 for at least 3 seconds, until 



 

changes to “-”. The speed display will show the current 

setting. 

 

Tap SW1 until 



and 

T CAL

 

are displayed. 

 

Press and hold SW1 until “-” and 

DONE

 are displayed. 

 

Tap SW1 until 



 and 

DONE

 are displayed. 

 

Press and hold SW1 until “-” and 

DONE

 are displayed. 

 

 
Obtaining engine temperature from the BIM-01-2-HLLY 

 

Hold the SW1 switch from the instrument system control box while turning the key on. 

o

 

The speed display should show 



 and the message display should show 

SETUP

 

Release SW1.  Tap SW1 until 



 and 

WATER

 are displayed. 

 

Press and hold SW1 for at least 3 seconds, until 



 

changes to “-”. The displays should show 



 and 

SENDER

 

Press and hold SW1 for at least 3 seconds, until 



 

changes to “-”. The speed display will show the current 

setting. 

 

Tap SW1 until 



 and 

BUS F

 (Fahrenheit) is displayed. 

o

 

Tap SW1 once more for 



 and 

BUS C

 (Celsius) if desired. 

 

Press and hold SW1 until “-” and 

DONE

 are displayed. 

 

Tap SW1 until 



 and 

DONE

 are displayed. 

 

Press and hold SW1 until “-” and 

DONE

 are displayed. 

 

 

 

Summary of Contents for BIM-01-2-HSN2

Page 1: ...aisy chained together Cannot daisy chain with GPS 50 2 Do not connect the I O port to anything other than a Dakota Digital control box or BIM Do not mount the module in the engine compartment as it sh...

Page 2: ...em setup No configuration within the Sniper EFI system or software is required BIM 01 2 HLLY setup The BIM must be configured to understand it will be talking to the Sniper EFI Hold button on BIM 01 2...

Page 3: ...ng the VFD3 setup is done by holding SW1 I and turning the ignition to on or acc Once in setup one can move between speed tach volt water etc by tapping SW1 I If you are setting multiple items once do...

Page 4: ...NGINE 8 will be displayed Tap SW1 I until ENGINE BUS is displayed Press and hold SW1 I until DONE is displayed Tap SW1 I until TACH DONE is displayed Press and hold SW1 I until a big DONE is displayed...

Page 5: ...elect EXIT SETUP to return to normal operation BOTH SWI left moves up the menu list SWII right moves down the menu list Obtaining RPM from the BIM 01 2 HLLY Tap SWII right switch until TACH is selecte...

Page 6: ...ayed Tap the Control Knob to enter CYLINDER menu Twist the Control Knob counterclockwise until BIM is highlighted Tap the knob to select BIM When INPUT is displayed again twist the Control Knob until...

Page 7: ...ent system or Tap the switch to change the system o Standard Dominator or Terminator HP o Sniper o Terminator X only To save setting press and hold the switch until you see on the display then release...

Page 8: ...models of Holley EFI systems Hold the switch on the BIM 01 2 HLLY case while turning the key on The BIM display will show the current revision code while this is held Release the switch Tap the switc...

Page 9: ...ed Module is damaged Connect to a location that has 12V key on power Inspect harness and repair or replace Return for service See Instructions below BIM display is scanning EFI adapter harness is not...

Page 10: ...s product that should it under normal use and condition be proven defective in material or workmanship for the lifetime of the original vehicle it was installed in such defect s will be repaired or re...