BIM setup continued:
Holley Handheld
Most Holley systems come with a handheld display which attaches to the Holley ECU. By default, this unit is programmed
to assume the Holley handheld is in use. If your Holley system does not have a Holley handheld unit attached, please
change this setting to ‘
NO
’
Note - If
you change this setting to ‘NO’, and plan to use a Holley CAN to USB adapter to perform Holley firmware
updates, you must disconnect this BIM module prior to the firmware update. After the firmware update is
complete, you can re-connect this BIM module.
•
Hold the switch on the BIM-01-2-HLLY case while turning the key on. The BIM display will show the current
revision code while this is held.
•
Release the switch.
•
Tap the switch until the display shows
(handheld). Press and hold to enter this menu.
•
When you see “---” on the display release the switch
•
The display will show the current setting,
(handheld attached) or
(handheld not attached).
•
Tap the switch to change the state.
•
To save setting press and hold the switch until you see
“
” on the display, then release the switch.
•
The display will show
. Press and hold the switch to exit setup or tap to choose another menu option.
Enabling Boost:
All Holley systems (except for Terminator X) will always send MAP/vacuum data to the BIM-01-2-HLLY.
The BIM-01-2-HLLY has an option to enable boost readings if the car has turbocharger, and this works on all models of
Holley EFI systems.
•
Hold the switch on the BIM-01-2-HLLY case while turning the key on. The BIM display will show the current
revision code while this is held.
•
Release the switch.
•
Tap the switch until the display shows
(boost). Press and hold to enter this menu.
•
When you see
“
” on the display release the switch.
•
The display will show the current boost state,
(disable) or
(enable).
•
Tap the switch to change the state.
•
To save setting press and hold the switch until you see
“
” on the display, then release the switch.
•
The display will show
. Press and hold the switch to exit setup or tap to choose another menu option.
To set or change the ID number:
The ID will not normally need to be changed. The fuel PSI and A/F ratio readings both use
bus ID’s so if you have other
BIM units connected along with this one, there is a chance of ID conflicts. This can easily be resolved. If fuel PSI or A/F
ratio is not showing up in the BIM setup menu on your system you may need to resolve an ID conflict. The following
procedure will allow the BIM-01-2 to automatically select a new, unused ID.
•
Hold the switch on BIM while turning the key on. The BIM will show the current software code.
•
Release the switch.
•
Press and release the switch until
is shown on the display.
•
Press and hold.
will be shown while the BIM is scanning the bus for other BIM units.
•
When you see
shown on the display release the switch.
•
The BIM unit will now go back to normal operation.
HDX/RTX TIP
: Intake/manifold air temp, Fuel PSI, boost and A/F ratio will be displayed in the group screens if activated
through the displays>>group set menu setup.