Dakota Digital BIM-01-2-HSN2 Quick Start Manual Download Page 8

 

[8] 

 

MAN #650832 

BIM setup continued: 
 

Holley Handheld 

Most Holley systems come with a handheld display which attaches to the Holley ECU. By default, this unit is programmed 
to assume the Holley handheld is in use. If your Holley system does not have a Holley handheld unit attached, please 
change this setting to ‘

NO

’  

 

Note - If 

you change this setting to ‘NO’, and plan to use a Holley CAN to USB adapter to perform Holley firmware 

updates, you must disconnect this BIM module prior to the firmware update. After the firmware update is 
complete, you can re-connect this BIM module.  

 

 

Hold the switch on the BIM-01-2-HLLY case while turning the key on.  The BIM display will show the current 
revision code while this is held. 

 

Release the switch. 

 

Tap the switch until the display shows 



(handheld). Press and hold to enter this menu.  

 

When you see “---” on the display release the switch  

 

The display will show the current setting, 



 (handheld attached) or 



 (handheld not attached).

 

 

Tap the switch to change the state.

 

 

To save setting press and hold the switch until you see 



” on the display, then release the switch.  

 

 

The display will show 



. Press and hold the switch to exit setup or tap to choose another menu option.

 

 
Enabling Boost: 

All Holley systems (except for Terminator X) will always send MAP/vacuum data to the BIM-01-2-HLLY. 
The BIM-01-2-HLLY has an option to enable boost readings if the car has turbocharger, and this works on all models of 
Holley EFI systems. 

 

Hold the switch on the BIM-01-2-HLLY case while turning the key on.  The BIM display will show the current 
revision code while this is held. 

 

Release the switch.   

 

Tap the switch until the display shows 



 (boost).  Press and hold to enter this menu. 

 

When you see 



” on the display release the switch.   

 

The display will show the current boost state, 



 (disable) or 



 (enable).

 

 

Tap the switch to change the state.

 

 

To save setting press and hold the switch until you see 



” on the display, then release the switch.  

 

 

The display will show 



. Press and hold the switch to exit setup or tap to choose another menu option.

 

 

To set or change the ID number: 

The ID will not normally need to be changed. The fuel PSI and A/F ratio readings both use 

bus ID’s so if you have other 

BIM units connected along with this one, there is a chance of ID conflicts. This can easily be resolved. If fuel PSI or A/F 
ratio is not showing up in the BIM setup menu on your system you may need to resolve an ID conflict. The following 
procedure will allow the BIM-01-2 to automatically select a new, unused ID. 

 

Hold the switch on BIM while turning the key on.  The BIM will show the current software code. 

 

Release the switch.   

 

Press and release the switch until 



 is shown on the display. 

 

Press and hold. 



 will be shown while the BIM is scanning the bus for other BIM units.   

 

When you see 



 shown on the display release the switch. 

 

The BIM unit will now go back to normal operation. 

 
HDX/RTX TIP

: Intake/manifold air temp, Fuel PSI, boost and A/F ratio will be displayed in the group screens if activated 

through the displays>>group set menu setup. 
 

Summary of Contents for BIM-01-2-HSN2

Page 1: ...aisy chained together Cannot daisy chain with GPS 50 2 Do not connect the I O port to anything other than a Dakota Digital control box or BIM Do not mount the module in the engine compartment as it sh...

Page 2: ...em setup No configuration within the Sniper EFI system or software is required BIM 01 2 HLLY setup The BIM must be configured to understand it will be talking to the Sniper EFI Hold button on BIM 01 2...

Page 3: ...ng the VFD3 setup is done by holding SW1 I and turning the ignition to on or acc Once in setup one can move between speed tach volt water etc by tapping SW1 I If you are setting multiple items once do...

Page 4: ...NGINE 8 will be displayed Tap SW1 I until ENGINE BUS is displayed Press and hold SW1 I until DONE is displayed Tap SW1 I until TACH DONE is displayed Press and hold SW1 I until a big DONE is displayed...

Page 5: ...elect EXIT SETUP to return to normal operation BOTH SWI left moves up the menu list SWII right moves down the menu list Obtaining RPM from the BIM 01 2 HLLY Tap SWII right switch until TACH is selecte...

Page 6: ...ayed Tap the Control Knob to enter CYLINDER menu Twist the Control Knob counterclockwise until BIM is highlighted Tap the knob to select BIM When INPUT is displayed again twist the Control Knob until...

Page 7: ...ent system or Tap the switch to change the system o Standard Dominator or Terminator HP o Sniper o Terminator X only To save setting press and hold the switch until you see on the display then release...

Page 8: ...models of Holley EFI systems Hold the switch on the BIM 01 2 HLLY case while turning the key on The BIM display will show the current revision code while this is held Release the switch Tap the switc...

Page 9: ...ed Module is damaged Connect to a location that has 12V key on power Inspect harness and repair or replace Return for service See Instructions below BIM display is scanning EFI adapter harness is not...

Page 10: ...s product that should it under normal use and condition be proven defective in material or workmanship for the lifetime of the original vehicle it was installed in such defect s will be repaired or re...

Reviews: