REYQ8~16M8W1B
VRVII System air conditioner
4PW23712-1
Installation manual
2
1.1.
Combination
The indoor units can be installed in the following range.
■
Always use appropriate indoor units compatible with R-410A.
To learn which models of indoor units are compatible with
R-410A, refer to the product catalogs.
■
Total capacity/quantity of indoor units
1.2.
Standard supplied accessories
Refer to
figure 15
.
1.3.
Optional accessories
To install the above outdoor units, the following optional parts are
also required.
■
Refrigerant branching kit (for R-410A only: Always use an
appropriate kit dedicated for your system.)
For 3 pipes:
For 2 pipes:
■
Outdoor unit multi connection piping kit (For R-410A only:
Always use an appropriate kit dedicated for your system.)
To select an optimum refrigerant branching kit, refer to
"6. Refrigerant
piping" on page 4
.
1.4.
Technical and electrical specifications
Refer to the Engineering Data Book for the complete list of
specifications.
2. M
AIN
COMPONENTS
For main components and function of the main components, refer to
the Engineering Data Book.
3. S
ELECTION
OF
LOCATION
This is a class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to
take adequate measures.
The inverter units should be installed in a location that meets the
following requirements:
1
The foundation is strong enough to support the weight of the unit
and the floor is flat to prevent vibration and noise generation.
2
The space around the unit is adequate for servicing and the
minimum space for air inlet and air outlet is available. (Refer to
figure 1
and choose one of the possibilities).
In case of an installation site where only the sides A+B have
obstacles, the wall heights have no influence on any indicated
service space dimensions.
Outdoor unit
Total capacity of
indoor units
Total quantity of
indoor units
REYQ8
(*)
100
~
260
13
REYQ10
(*)
125
~
325
16
REYQ12
(*)
150
~
390
19
REYQ14
(*)
175
~
455
20
REYQ16
(*)
200
~
520
20
REYQ18
225
~
585
20
REYQ20
250
~
650
20
REYQ22
275
~
715
22
REYQ24
300
~
780
32
REYQ26
325
~
845
32
REYQ28
350
~
910
32
REYQ30
375
~
975
32
REYQ32
400
~
1040
32
REYQ34
425
~
1105
34
REYQ36
450
~
1170
36
REYQ38
475
~
1235
38
REYQ40
500
~
1300
40
REYQ42
525
~
1365
40
REYQ44
550
~
1430
40
REYQ46
575
~
1495
40
REYQ48
600
~
1560
40
(*) = main units
Suction gas line piping (1)
1
Suction gas line piping (2)
1
Suction gas line piping (3)
1
Discharge gas line
piping (1)
1
REYQ8
12
16
Discharge gas line piping (2) 1
Discharge gas line piping (3) 1
Installation manual
Operation manual
1
1
Additional refrigerant charge
label
1
1
Installation and operational manual
2
Accessory pipes
Refnet header
Refnet joint
—
KHRQ23M20T
KHRQ23M29H
KHRQ23M29T
KHRQ23M64H
KHRQ23M64T
KHRQ23M75H
KHRQ23M75T
Refnet header
Refnet joint
—
KHRQ22M20T
KHRQ22M29H
KHRQ22M29T
KHRQ22M64H
KHRQ22M64T
Number of outdoor units connected
2
3
BHFQ23M907
BHFQ23M1357
■
Make sure to provide for adequate measures in order
to prevent that the outdoor unit be used as a shelter
by small animals.
■
Small animals making contact with electrical parts can
cause malfunctions, smoke or fire. Please instruct the
customer to keep the area around the unit clean.
A B C D
Sides along the installation site with obstacles
Suction side