![Daikin Super Multi Plus E-Series BPMKS967B2B Service Manual Download Page 347](http://html1.mh-extra.com/html/daikin/super-multi-plus-e-series-bpmks967b2b/super-multi-plus-e-series-bpmks967b2b_service-manual_2459148347.webp)
SiBE18-821_C
Service Check Function
Troubleshooting
335
Check Method 2
1. Press the center of the Temp button and the Mode button at the same time.
“
5C
” is displayed on the LCD.
2. Select “
5C
” (service check) with the Temp
▲
or
▼
button.
3. Press the Mode button to enter the service check mode.
The figure of the ten’s place blinks.
4. Press the Temp
▲
or
▼
button and change the figure until you hear the sound of “beep” or
“pi pi”.
5. Diagnose by the sound.
★
“pi” : The figure of the ten’s place does not accord with the error code.
★
“pi pi” : The figure of the ten’s place accords with the error code but the one’s not.
★
“beep” : The both figures of the ten’s and one’s place accord with the error code.
(The figures indicated when you hear the “beep” sound are error code.
→
Refer to page 350, 351.)
(R11669)
(R11821)
(R11670)
(R11671)