RA Indoor Unit
SiBE18-821_C
180
Operation Manual
3.1.6 POWERFUL Operation
18
POWERFUL Operation
To start POWERFUL operation
Press
during operation.
To cancel POWERFUL operation
Press again.
• “ ” disappears from the LCD.
[Example]
Normal operation
POWERFUL operation
NOTE
POWERFUL operation quickly maximizes the cooling (heating) effect in any
operation mode. You can get the maximum capacity.
• POWERFUL operation ends in 20 minutes. Then the system automatically operates
again with the previous settings which were used before POWERFUL operation.
• “ ” is displayed on the LCD.
Back to normal
operation
• POWERFUL operation will
work for 20 minutes.
• When you want to get the
cooling effect quickly, start
the POWERFUL operation.
Notes on POWERFUL operation
• When using POWERFUL operation, there are some functions which are not available.
• POWERFUL operation cannot be used together with ECONO, COMFORT AIRFLOW or OUTDOOR UNIT QUIET operation.
Priority is given to the function of whichever button is pressed last.
• POWERFUL operation can only be set when the unit is running. Pressing causes the settings to be canceled, and the “ ” disappears
from the LCD.
• POWERFUL operation will not increase the capacity of the air conditioner if the air conditioner is already in operation with its maximum
capacity demonstrated.
•
In COOL and HEAT operation
To maximize the cooling (heating) effect, the capacity of outdoor unit must be increased and the airflow rate be fixed to the maximum setting.
The temperature and airflow settings are not variable.
•
In DRY operation
The temperature setting is lowered by 2.5˚C and the airflow rate is slightly increased.
•
In FAN operation
The airflow rate is fixed to the maximum setting.
•
In AUTO operation
To maximize the cooling (heating) effect, the capacity of outdoor unit must be increased and the airflow rate be fixed to the maximum setting.