Indoor Unit Control (RA Models)
Function
103
Floor / Ceiling Suspended Dual Type
3-D Airflow
Wall Mounted Type E-Series, G-Series, F-Series
Alternative repetition of vertical and horizontal swing motions enables uniform air-conditioning of
the entire room. This function is effective for starting the air conditioner.
When the horizontal swing and vertical swing are both set to auto mode, the airflow becomes 3-
D airflow. The horizontal and vertical swing motions are alternated and the airflow direction
changes in the order shown in the following diagram.
(1) The vertical blades (louvers) move from the right to the left.
(2) The horizontal blades (flaps) move downward.
(3) The vertical blades (louvers) move from the left to the right.
(4) The horizontal blades (flaps) move upward.
COMFORT
AIRFLOW
Operation
Wall Mounted Type E-Series, J-Series, G-Series
The vertical swing flap is controlled not to blow the air directly on the person in the room.
Vertical Swing (up and down)
Cooling / Dry / Fan
Heating
Ceiling
(R2964)
(R2963)
Floor
(R2967)
(R2966)
40˚
20˚
95˚
65˚
40˚
20˚
95˚ 65˚
(2)
(1)
(4)
(3)
(R13524)
Cooling / Dry
Heating
(R14073)
(R14074)
A
B
J-Series
5°
75°
E-Series
G-Series 20-50 Class
5°
80°
G-Series 60/71 Class
5°
55°
A
B