SiBE18-821_C
RA Indoor Unit
Operation Manual
179
17
INTELLIGENT EYE Operation
NOTE
Notes on INTELLIGENT EYE operation
• Application range is as follows.
90˚
55˚
7m
55˚
Vertical angle 90˚
(Side view)
Horizontal angle 110˚
(Top view)
7m
Page 21
CAUTION
[Example]
When somebody in the room
Normal operation
When nobody in the room
Somebody back in the room
Back to normal operation.
INTELLIGENT EYE operation is useful for energy saving
Energy saving operation
• The air conditioner is in normal
operation while the sensor is
detecting the movement of people.
• The air conditioner will return to
normal operation when the sensor
detects the movement of people
again.
20 minutes after, start
energy saving operation.
• The set temperature is shifted in
±2˚C steps.
• If no presence detected in the room for 20 minutes, the energy saving operation will start.
• This operation changes the temperature –2˚C in HEAT / +2˚C in COOL / +1˚C in DRY operation from set temperature.
• This operation decreases the airflow rate slightly in FAN operation only.
• Sensor may not detect moving objects further than 7m away. (Check the application range.)
• Sensor detection sensitivity changes according to indoor unit location, the speed of passersby, temperature range, etc.
• The sensor also mistakenly detects pets, sunlight, fluttering curtains and light reflected off of mirrors as passersby.
• INTELLIGENT EYE operation will not go on during POWERFUL operation.
• NIGHT SET mode will not go on during use of INTELLIGENT EYE operation.
• Do not place large objects near the sensor.
Also keep heating units or humidifiers outside the sensor’s detection area. This sensor can detect undesirable objects.
• Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and malfunction.