![background image](http://html1.mh-extra.com/html/daikin/super-multi-nx-ffq25b8v1b/super-multi-nx-ffq25b8v1b_service-manual_4061781031.webp)
SiBE121021_C
Specifications
Specifications
19
50 Hz, 220 - 230 - 240 V
Model
FTXS50G2V1B
FTXS20J2V1B
Rated Capacity
5.0 kW Class
2.0 kW Class
Front Panel Color
White
White
Airflow Rates
H
m³/min
(cfm)
10.2 (360)
9.4 (332)
M
8.6 (305)
7.4 (261)
L
7.0 (246)
5.5 (194)
SL
6.0 (212)
4.1 (145)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
23
23
Speed
Steps
5 Steps, Quiet, Auto
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable / Washable / Mildew Proof
Removable / Washable / Mildew Proof
Running Current (Rated)
A
0.12 - 0.12 - 0.11
0.09 - 0.08 - 0.08
Power Consumption (Rated)
W
26 - 26 - 26
18 - 18 - 18
Power Factor (Rated)
%
98.5 - 94.2 - 98.5
90.9 - 97.8 - 93.8
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H × W × D)
mm
295 × 800 × 215
295 × 800 × 215
Packaged Dimensions (H × W × D)
mm
274 × 870 × 366
289 × 870 × 366
Weight (Mass)
kg
10
9
Gross Weight (Gross Mass)
kg
13
13
Operation
Sound
H / M / L / SL
dB(A)
43 / 39 / 34 / 31
38 / 32 / 25 / 22
Sound Power
dB(A)
59
54
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping
Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
12.7
φ
9.5
Drain
mm
φ
18.0
φ
18.0
Drawing No.
3D059731
3D070569A
Model
FTXS25J2V1B
FTXS35J2V1B
Rated Capacity
2.5 kW Class
3.5 kW Class
Front Panel Color
White
White
Airflow Rates
H
m³/min
(cfm)
10.8 (381)
11.4 (403)
M
7.9 (279)
8.7 (307)
L
5.2 (184)
5.8 (205)
SL
3.7 (131)
4.4 (155)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
23
23
Speed
Steps
5 Steps, Quiet, Auto
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable / Washable / Mildew Proof
Removable / Washable / Mildew Proof
Running Current (Rated)
A
0.09 - 0.08 - 0.08
0.12 - 0.12 - 0.11
Power Consumption (Rated)
W
18 - 18 - 18
26 - 26 - 26
Power Factor (Rated)
%
90.9 - 97.8 - 93.8
98.5 - 94.2 - 98.5
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H × W × D)
mm
295 × 800 × 215
295 × 800 × 215
Packaged Dimensions (H × W × D)
mm
289 × 870 × 366
289 × 870 × 366
Weight (Mass)
kg
9
10
Gross Weight (Gross Mass)
kg
13
14
Operation
Sound
H / M / L / SL
dB(A)
41 / 33 / 25 / 22
45 / 37 / 29 / 23
Sound Power
dB(A)
57
61
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping
Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
9.5
φ
9.5
Drain
mm
φ
18.0
φ
18.0
Drawing No.
3D070570A
3D070571A
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3