![Daikin Super Multi NX FFQ25B8V1B Service Manual Download Page 329](http://html1.mh-extra.com/html/daikin/super-multi-nx-ffq25b8v1b/super-multi-nx-ffq25b8v1b_service-manual_4061781329.webp)
SiBE121021_C
Troubleshooting for RA Indoor Unit - F(C)TXG, FTXS, ATXS, FVXS, FLK(X)S, FDK(X)S Series
Service Diagnosis
317
Troubleshooting
Check No.11
Refer to P.363
Check the voltage of the indoor
unit-outdoor unit connection wires
between No. 1 and No. 3, and
between No. 2 and No. 3.
Check No.11
Check the power supply
waveform.
YES
YES
Replace the indoor unit PCB.
Locate the cause of the
disturbance of the power
supply waveform, and correct
it.
NO
(R14556)
NO
YES
YES
NO
NO
Caution
Correct the indoor unit -
outdoor unit connection wires.
Diagnose the outdoor unit
PCB.
Replace the connection wires
between the indoor and
outdoor units.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Check the indoor unit - outdoor
unit connection wires.
Is there any wiring error?
Properly insulated?
Check the LED A on the outdoor
unit PCB.
Is LED A blinking?
Is there any disturbance?